Ultra‐fast dosimetric data collection with a commercial plastic scintillation detector in an MR‐linac

Read full text
Authors: Carlos F. Sanchez Ferrer, Concepción Huertas, Marcos Feijoo, Alessandro Cardin, Moisés Sáez
Cited by: 1
References: 41

Abstract

Abstract Background Plastic scintillation detectors (PSD) are widely used for detecting and measuring ionizing radiation. These detectors are versatile, with high efficiency, fast response and the ability to provide real‐time measurements. Purpose Evaluate the suitability of Blue Physics PSD (BP‐PSD) for performing ultra‐fast dosimetric commissioning measurements with high accuracy and precision in a very short time. Methods Ultra‐fast measurements were performed in water using a BP‐PSD on an Elekta Unity MR‐linac. Percentage depth doses (PDD) and profiles at different depths were measured at two movement velocities, 10 mm/s and 20 mm/s, for field sizes ranging from 10 × 10 cm 2 to 1 × 1 cm 2 . Gamma analysis was conducted to compare these measurements with those obtained during machine commissioning using a PTW Semiflex 3D ionization chamber (for PDD) and a PTW micro‐Diamond detector (for PDD and profiles). Gamma criteria of 2%/2 mm and 1%/1 mm dose difference/distance to agreement were studied, alongside field size, penumbra, and measurement time. Results All PDD and profile gamma passing rates were 100% at 2%/2 mm. At the stricter 1%/1 mm criteria, all PDD showed a passing rate above 96.97% for both velocities, with most of the profiles exceeding 95% at 10 mm/s and 90% at 20 mm/s. Gamma analysis results were superior for smaller fields (1 × 1 cm 2 and 2 × 2 cm 2 ) and generally better at 10 mm/s. On average, the penumbra measurements obtained with the PSD were greater than those achieved with the micro‐Diamond detector. Measurement times were found to be between 7 and 14 times shorter for PDD, and between 5 and 9 times shorter for profiles at speeds of 10 mm/s and 20 mm/s, respectively. Conclusions Ultra‐fast measurements using the Blue Physics PSD are suitable for acquiring dosimetric commissioning data with high accuracy and precision, and can be performed in a much shorter timeframe than with commonly used detectors.

Fields of Study & Subjects

Radiation Effects and Dosimetry Advanced Radiotherapy Techniques Radiation Therapy and Dosimetry

Publication details

Journal / source
Journal of Applied Clinical Medical Physics
Publisher
Wiley
Volume
27
Issue
1
Pages
e70460–e70460
Publication date
1 January 2026
Language
EN