Clinical evaluation of two new unshielded and shielded silicon diode detectors in external photon beam radiation therapy: SunSILICON and SunSILICON P

Read full text
Authors: Teresa J. Anders, Veronika Flatten, Mohamad Alissa, David Towle, Andy Murray, Ann‐Britt Schönfeld, Erik Alquist, Olivier Evrard, Jeff Hildreth, Ndimofor Chofor, Gerhard Wessing, Charbel Habib
+2 more Damian Czarnecki, Andreas A. Schönfeld
Cited by: 3
References: 24

Abstract

BACKGROUND: Advanced external photon beam radiotherapy requires dosimetry detectors with high spatial resolution and minimal perturbation effects. Silicon diode detectors are widely used due to their high sensitivity and small sensitive volumes, but fluence perturbation effects and energy dependence can affect performance and depend on detector construction. Shielded and unshielded configurations are used to address these challenges, but their clinical performance and limitations require systematic evaluation. PURPOSE: This study aims to evaluate the clinical performance of two newly developed silicon diode detectors-SunSILICON (unshielded) and SunSILICON P (shielded)-for relative dosimetry in external photon beam radiotherapy. The detectors' response behaviors are compared to established detectors across the full clinical range of field sizes and beam energies, focusing on percentage depth dose (PDD) and lateral beam profile measurements. METHODS: Co unit, using various types of motorized water phantoms. Comparative measurements were performed with ionization chambers, as well as other silicon and diamond detectors. Over 600 scans were analyzed, and gamma analysis was applied to assess agreement using 0.5%/0.5 mm for PDDs and 1%/1 mm for lateral beam profiles. Angular dependence, detector sensitivity and the effective point of measurement (EPOM) were determined in solid phantoms. RESULTS: SunSILICON and SunSILICON P demonstrated excellent agreement with established detectors within their specified field size ranges. Gamma passing rates exceeded 99% for most comparisons, with minor deviations in large fields or at field size limits. The shielded SunSILICON P showed reduced energy dependence in large fields compared to the unshielded version, while SunSILICON showed superior performance in small fields. Both detectors exhibited minimal angular dependence (

Fields of Study & Subjects

Advanced Radiotherapy Techniques Radiation Therapy and Dosimetry Radiation Detection and Scintillator Technologies

Publication details

Journal / source
Journal of Applied Clinical Medical Physics
Publisher
Wiley
Volume
27
Issue
4
Pages
e70576–e70576
Publication date
1 April 2026
Language
EN