Use of apertures in single‐energy pristine Bragg peak FLASH radiotherapy

Read full text
Authors: Y H Ma, Balaji Selvaraj, Xingyi Zhao, Chingyun Cheng, Chin-Cheng Chen, Longfei Diao, Yufei Wang, Zhengda Wang, Yuntong Pei, L J Liu, Xueqing Yan, Benjamin Durkee
+4 more Charles B Simone, Haibo Lin, Xuanqin Mou, Minglei Kang
Cited by: 1
References: 59

Abstract

Abstract Background Proton single‐energy Bragg peak (SEBP) FLASH delivery can achieve dosimetric distributions equivalent to conventional intensity‐modulated proton therapy (IMPT). However, range‐pulling and field compensator devices enlarge the proton pencil beam spot size, increasing lateral penumbra and compromising dose conformality and high‐dose‐rate distribution. Apertures are employed to mitigate these effects, enhancing dose metrics while preserving ultra‐high dose rate performance. Purpose To investigate the efficacy of apertures in sharpening lateral dose falloff and enhancing dose conformity in proton pencil beam scanning (PBS) Bragg peak (BP) FLASH radiotherapy (RT), addressing increased lateral dose spillage caused by universal range shifter (URS) and range compensator (RC) usage. Methods PBS Single‐energy BP (SEBP) FLASH treatment plans with and without brass apertures were optimized using an in‐house planning system. Dose and dose rate characteristics were simulated using MCSquare. Penumbra reduction was assessed in a water phantom for 3 and 5 cm square fields under varying pullback (10 cm, 20 cm. 30 cm) and air gap (5 cm, 10 cm, 15 cm) conditions. Aperture effects were evaluated at the entrance, midpoint, and BP positions. The rGBM cancer plan was optimized using SEBP with various dose thresholds (0, 2, and 5 Gy) applied to analyze dose and ultra‐high dose rate (V 40Gy(RBE)/s ) performance. Results Use of aperture significantly reduced lateral penumbra across all spatial positions. The degree of penumbra reduction increased significantly with the increased pullback, and the reduction effect at the BP was generally comparable to that at the entrance. The 5 cm field generally showed greater penumbra reduction than the 3 cm field. In the rGBM case, apertures improved gross tumor volume (GTV) dose conformity and reduced organ‐at‐risk (OAR) exposure but decreased ultra‐high dose rate coverage for both GTV and OARs. The ultra‐high dose rate coverage of GTV was not affected by the dose threshold, while the ultra‐high dose rate coverage of the brain increased with the increasing dose threshold. Conclusion Apertures effectively reduce lateral penumbra and dose spalliage to OARs, improving target dose conformity in range shifter‐based SEBP FLASH‐RT. They also can reduce ultra‐high dose‐rate exposure to critical OARs in the low‐dose region while maintaining the FLASH ratio in the high‐dose region.

Fields of Study & Subjects

Radiation Therapy and Dosimetry Advanced Radiotherapy Techniques Boron Compounds in Chemistry

Publication details

Journal / source
Journal of Applied Clinical Medical Physics
Publisher
Wiley
Volume
27
Issue
5
Pages
e70593–e70593
Publication date
28 April 2026
Language
EN