Hydrogel Microneedle‐Integrated Electrochemical Sensor With Negative‐Potential Readout Toward Wash‐Free and Anti‐Interference Monitoring of miRNAs in Tumor Interstitial Fluid
Abstract
Electrochemical quantification of microRNAs (miRNAs) in tumor interstitial fluid (TIF) may provide complementary molecular information for tumor microenvironment assessment, but analytical accuracy is often limited by extraction-induced biomarker loss/degradation and background interference from endogenous electroactive metabolites. Herein, a hydrogel microneedle-integrated electrochemical biosensor is developed as a complementary ex vivo molecular sensing approach for wash-free and anti-interference monitoring of miRNAs via negative-potential readout. The sensing platform employs a four-way junction (FWJ) nucleic acid nanoreservoir to encapsulate the electroactive indicator doxorubicin (DOX), which is released upon target miRNA-triggered strand displacement. The characteristic oxidation potential of DOX (-0.65 V) enables detection in a negative potential window, thereby reducing co-oxidation interference by endogenous electroactive species. The porous hydrogel microneedle architecture facilitates rapid TIF sampling and directional diffusion of released DOX toward the electrode interface. The biosensor achieved a detection limit of 1.25 pM for miRNA-21 with an interassay variability of
Fields of Study & Subjects
Advanced biosensing and bioanalysis techniques
Advancements in Transdermal Drug Delivery
Microbial Inactivation Methods
Publication details
- Journal / source
- Advanced Healthcare Materials
- Pages
- e71694–e71694
- Publication date
- 7 September 2026
- Language
- EN