Catastrophic Degradation in Solid Oxide Fuel Cells Caused by Air Supply Interruption in Real‐World Operations: Fundamental Mechanisms and Mitigation Strategies (Adv. Sci. 3/2026)

Read full text
Authors: Haewon Seo, Ji-Eun Won, Wooseok Lee, Haneul Choi, Sun‐Young Park, Younghun Shin, Insung Lee, Tae Jin Lim, Kyeounghak Kim, Jongsup Hong, Hye Jung Chang, Kyung Joong Yoon
Cited by: 0

Abstract

Air Shortage-Induced Degradation in Solid Oxide Fuel Cells This cover image illustrates the degradation of solid oxide fuel cells during air supply interruption. When the air blower fails, oxygen is depleted, the cathode consumes lattice oxygen, and the resulting structural collapse sets off a chain of chemical degradation events. Strontium is identified as the critical trigger of this process, and the authors design a Sr-free cathode material that successfully prevents degradation and enables stable operation. More details can be found in the Research Article by Kyung Joong Yoon, Hye Jung Chang, Jongsup Hong, and co-workers (DOI: 10.1002/advs.202516807).

Fields of Study & Subjects

Advancements in Solid Oxide Fuel Cells Fuel Cells and Related Materials High-Temperature Coating Behaviors

Publication details

Journal / source
Advanced Science
Volume
13
Issue
3
Publication date
1 January 2026