Design considerations impacting flow dynamics in packed beds for virus inactivation

View at publisher
Authors: Innara Basria, Opeyemi O. Ajayi, Madaisabel FuentesArias, Ashley Osuna Najarro, Scott C. Lute
Cited by: 0
References: 18

Abstract

Despite significant advances in continuous manufacturing of monoclonal antibodies, the implementation of continuous virus inactivation (CVI) remains challenging due to standardization gaps that could compromise product quality and safety. This study identified limitations in minimum residence time (mRT) prediction for packed bed reactors (PBR) utilized for CVI. This work focused on characterizing the residence time distribution (RTD) behavior of tracers with varying molecular properties in four PBR configurations. The results demonstrated that tracer molecular size impacted mRT prediction, with larger molecules showing shorter residence times than smaller molecule tracers under identical conditions. During scale-up from 16 to 26 mm diameter columns, mRT was not maintained, suggesting that traditional chromatography scale-up principles may not be directly applicable to CVI using PBRs. Overall, this work established a helpful foundational understanding of how process material properties impact mRT prediction-a critical process parameter that would directly impact virus inactivation efficacy in integrated CVI systems.

Fields of Study & Subjects

Protein purification and stability Fluid Dynamics and Mixing Granular flow and fluidized beds

Publication details

Journal / source
Biotechnology Progress
Volume
42
Issue
2
Pages
e70103–e70103
Publication date
10 January 2026
Language