Does Sirolimus‐Eluting Resorbable Magnesium Scaffold Plays a Role in Iatrogenic Flow‐Limiting Coronary Artery Dissection?

View at publisher
Authors: Abdelrahman Elhakim, Mohamed Elhakim, Mohammed F. Saad, Osama Bisht
Cited by: 0
References: 1

Abstract

BACKGROUND: The third-generation sirolimus-eluting resorbable magnesium scaffold could be a competitive or alternative to a drug-eluting stent in the future, in particular in iatrogenic coronary artery dissection, to avoid unnecessary metal stents to reduce restenosis and occlusion rate. CASE PRESENTATION: We report a 66-year-old female who presented with unstable angina. The significant medial Cx stenosis was treated with a drug-coated balloon. A small new dissection medial Cx occurred. 8 hours later, the patient developed lateral wall ST segment elevation myocardial infarction. Coronary angiography revealed Cx with iatrogenic antegrade and retrograde propagation flow limiting dissection. After dissection modification with cuttering technique, we performed IVUS-guided medial to distal Cx with Freesolve BRS. The 3-month follow-up was uneventful. CONCLUSION: Usage of BRS in cases of iatrogenic flow limiting coronary artery dissection, especially in small diameter vessels, may be a good indication in the future to decrease the in-stent stenosis/occlusion rate. Large cohort studies are required.

Fields of Study & Subjects

Coronary Interventions and Diagnostics Magnesium Alloys: Properties and Applications Cardiac Imaging and Diagnostics

Publication details

Journal / source
Catheterization and Cardiovascular Interventions
Volume
107
Issue
5
Pages
1312–1313
Publication date
18 January 2026
Language
EN