Assessment of the utility of optically pumped magnetometer magnetoencephalography in preoperative localization of refractory epilepsy: A prospective study

Read full text
Authors: Yuanzhong Shen, Chao You, Y X Zhang, Nan Ji, Xu Zhao, Ping Zhang, Shanshan Huang, Huicong Kang, Xiaoyan Liu, Yuming Peng, Chang Sun, Bing Yan
+8 more Y X Zhang, S R Zhu, Wenzhen Zhu, Ting Lei, Zhouping Tang, Ming Lei Ding, Feng Hu, Kai Shu
Cited by: 1
References: 43

Abstract

OBJECTIVE: Precise localization of the epileptogenic zone (EZ) is crucial for epilepsy surgery success. Optically pumped magnetometer magnetoencephalography (OPM-MEG) is a promising noninvasive technique requiring rigorous clinical validation. METHODS: In this prospective diagnostic study, 68 patients with refractory epilepsy underwent 90-min interictal OPM-MEG. Dipoles were fitted to interictal epileptiform discharges for localization. The primary objective was to evaluate the spatial concordance between OPM-MEG and the EZ defined by intracranial electroencephalography (iEEG; stereo-EEG or electrocorticography), assessed at the sublobar level using Gwet AC1. The secondary objective was to evaluate the diagnostic value of OPM-MEG for surgical outcome. This analysis included 51 patients who underwent curative intervention (resection or thermocoagulation). The reference standard was a composite of the treated brain region and seizure freedom (International League Against Epilepsy [ILAE] class 1 or Engel class I) at ≥12-month follow-up, from which sensitivity, specificity, and diagnostic odds ratio (OR) were calculated. RESULTS: OPM-MEG showed almost perfect agreement with iEEG-based EZ localization overall (AC1 = .885, concordance rate = 90.0%), with substantial agreement in temporal (80.1%, AC1 = .723) and almost perfect agreement in extratemporal regions (92.0%, AC1 = .926). The Euclidean centroid distance between OPM-MEG and iEEG localizations was significantly shorter in concordant versus discordant cases. In the assessment of diagnostic value, OPM-MEG demonstrated a sensitivity of 85.7% and specificity of 65.2% (OR = 11.25) under ILAE criteria, and a sensitivity of 73.0% and specificity of 64.3% (OR = 4.86) under Engel criteria. SIGNIFICANCE: OPM-MEG demonstrates high concordance with iEEG for EZ localization and provides robust diagnostic value for predicting postoperative seizure freedom, supporting its utility in the presurgical evaluation of refractory epilepsy.

Fields of Study & Subjects

Atomic and Subatomic Physics Research Epilepsy research and treatment Functional Brain Connectivity Studies

Publication details

Journal / source
Epilepsia
Publisher
Wiley
Volume
67
Issue
8
Pages
3937–3954
Publication date
2 June 2026
Language
EN