Enhancing Study Design and Analysis of MR Imaging Markers Through Measurement Error Modeling
Abstract
BACKGROUND: Measurement error in imaging reduces statistical power and potentially biases parameter estimation, compromising study reliability. PURPOSE: To introduce a dual data collection design (reliability and main datasets) to quantify measurement error and apply regression calibration to correct error-prone imaging markers, thereby improving biomarker-outcome estimation, statistical power, and sample size planning. STUDY TYPE: Prospective (reliability) and retrospective (regression calibration). POPULATION: 65 healthy volunteers (mean age: 23.2), 60 age and sex matched with 34 epilepsy patients (mean age: 28.7). FIELD STRENGTH/SEQUENCE: 3.0 T, MR fingerprinting (MRF) and T1-weighted (T1w) MPRAGE. ASSESSMENT: ) for MRF T1 and T1w signal intensity (SI) mean and standard deviation (SD). These coefficients were applied in regression calibration to correct imaging markers in the epilepsy cohort. Effect sizes for distinguishing lesional from control were compared before and after correction. Simulations evaluated the impact of additive and proportional bias on sample size, statistical power, and association estimates under single and multi-scanner scenarios. STATISTICAL TEST: Reliability coefficient, Cohen's d, regression calibration, generalized estimation equations. RESULTS: = 0.246-0.554). Regression calibration increased effect size more for T1w SI mean (333.22% increase) than for MRF T1 mean (12.57% increase). In multi-site simulations, regression calibration alone achieved unbiased estimate under small site effects (additive and proportional SD ≤ 0.2), whereas under larger site effects (additive SD ≥ 0.5) only the combined regression calibration and Combat produced near-zero bias (-0.024), outperforming naïve analysis (-0.423). DATA CONCLUSION: The dual data acquisition design with regression calibration restores attenuated imaging biomarker associations, improves statistical power, and informs sampling requirements, thus enhancing reliability and generalizability in multi-site imaging studies. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: 2.
Fields of Study & Subjects
Advanced MRI Techniques and Applications
Epilepsy research and treatment
Functional Brain Connectivity Studies
Publication details
- Journal / source
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Volume
- 63
- Issue
- 6
- Pages
- 1596–1609
- Publication date
- 2 January 2026
- Language
- EN