A MR Fingerprinting Development Kit for Quantitative 3D Brain Imaging

Read full text Summarise with VIRAT
Authors: Rasim Boyacıoğlu, T. Kluge, Guido Buonincontri, Wei‐Ching Lo, Stephan Kannengießer, Mathias Nittka, Arashdeep Kaur, Andrew Dupuis, Dan Ma, Chaitra A. Badve, Mark Alan Griswold, Yong Chen
Cited by: 0
References: 25

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

ABSTRACT Background Magnetic resonance fingerprinting (MRF) is an emerging quantitative imaging technique that enables multiparametric tissue characterization, but its adoption has been hindered by the complexity of data acquisition and post‐processing. These technical and implementation challenges have limited its broader clinical deployment. Purpose To develop a modular MRF Development Kit (MRFDK) that enables efficient sequence design, streamlined implementation, and real‐time image reconstruction. Study Type Prospective. Population T 1 and T 2 relaxation phantom, nine volunteers (seven males and two females), five metastatic brain cancer patients. Field Strength/Sequence 3 T, MR Fingerprinting. Assessment Accuracy of T 1 and T 2 quantification was estimated from phantom experiments. Manual ROIs were drawn on brain lesions and contralateral white matter for metastatic cancer patients. Statistical Tests t ‐test, in vivo repeatability was calculated with Bland–Altman analysis on healthy volunteer scan‐rescan data, significance level p < 0.01. Results Phantom results showed high accuracy in T 1 and T 2 assessment, with absolute percentage differences of 3% for T 1 and 5% for T 2 compared to offline MATLAB reconstruction. In vivo scans of eight healthy subjects further demonstrated excellent repeatability (bias and agreement: 0.95% ± 1.85% for T 1 ; 1.78% ± 5.08% for T 2 ). In patients, metastatic lesions showed significantly higher T 1 and T 2 values (T 1 , 1474 ms; T 2 , 61 ms) compared to normal white matter (T 1 , 913 ms; T 2 , 38 ms). With integrated B 1 correction, all T 1 and T 2 maps were available for visualization within 1 min post‐MRF scan, enabling immediate image assessment. Data Conclusion A modular MRF development package enabling efficient 3D acquisition and rapid inline reconstruction was developed and evaluated in this study. Level of Evidence 1. Technical Efficacy Stage 2.

Fields of Study & Subjects

Advanced MRI Techniques and Applications NMR spectroscopy and applications Advanced Neuroimaging Techniques and Applications

Publication details

Journal / source
Journal of Magnetic Resonance Imaging
Volume
64
Issue
1
Pages
209–217
Publication date
28 March 2026
Language
EN