Deep Learning‐Accelerated MRI Assessment of Hepatic Proton Density Fat Fraction: Agreement With Conventional Acquisition Across Manual and Automated Measurement Approaches

View at publisher
Authors: Seo Yeon Youn, Bohyun Kim, Hyunsoo Lee, Jungwoo Lee, Seohyun Choi, Dominik M. Nickel, Sabine Mollus, Stephan Kannengießer, Joon‐Il Choi, Yu Ri Shin, Soon Nam Oh, Sung Eun Rha
Cited by: 1
References: 23

Abstract

BACKGROUND: Deep learning reconstruction can shorten breath-hold MRI for liver proton density fat fraction (DL-PDFF), but agreement with conventional PDFF (Conv-PDFF) and the impact of measurement approach (regional vs. whole-liver segmentation) remain unclear. PURPOSE: To evaluate linearity and agreement of DL-PDFF with Conv-PDFF and MR spectroscopy PDFF (MRS-PDFF), and reconstruction-dependent whole-liver distribution metrics. STUDY TYPE: Retrospective. POPULATION: Fat phantom three vials per nominal fat mass fraction (27.86%, 18.32%, and 9.12%); 96 adults (53 males; median age, 64). FIELD STRENGTH/SEQUENCE: 3 T; Chemical shift-encoded multi-echo gradient-echo; acquisition time, 10 s (DL-PDFF; acceleration factor [AF], 6) and 14 s (Conv-PDFF; AF, 4). ASSESSMENT: Central region of interest (ROI) for phantom PDFF; In vivo, single ROI by radiology technologists, multiple ROIs by a resident and a medical student, and automated whole-liver segmentation, yielding voxel-based histograms and residual fitting error; inter-observer agreement. STATISTICAL TESTS: ), Bland-Altman bias and 95% limits of agreement (LoA) with proportional-bias slope (β), Lin's concordance correlation coefficient (CCC), Hodges-Lehmann method, and Spearman (ρ). Two-sided p < 0.05. RESULTS: = 1.00). In patients, within the same approach: single ROI (bias, -0.24%; widest LoA, -2.76 to 2.28; CCC, 0.94); multiple ROIs (bias, -0.002; LoA, -1.04 to 1.04; CCC, 0.99); and whole-liver segmentation (bias, 0.12; LoA, -0.54 to 0.78; CCC, 0.99). Cross-method comparison (DL-PDFF segmentation vs. Conv-PDFF multiple ROIs) showed larger bias (0.57; LoA, -0.77 to 1.91; CCC, 0.97). Against MRS-PDFF, bias was similar (-0.05 to -0.02; LoA, -3.00 to 2.96). For DL-PDFF, whole-liver SD (Hodges-Lehmann difference, 0.55%; ρ = 0.95) and residual fitting error significantly higher (median, 2.80 vs. 1.92). Inter-observer agreement was high (CCC, 0.99). DATA CONCLUSION: DL-PDFF demonstrated high agreement with Conv-PDFF while reducing acquisition time. However, measurement approach (segmentation vs. ROI) contributes larger systematic differences relevant to longitudinal and cross-study comparisons. EVIDENCE LEVEL: 3. STAGE OF TECHNICAL EFFICACY: 2.

Fields of Study & Subjects

Liver Disease Diagnosis and Treatment Hepatocellular Carcinoma Treatment and Prognosis Advanced MRI Techniques and Applications

Publication details

Journal / source
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Publication date
16 August 2026
Language
EN