Safety and Feasibility of Deep Sedation With a Tulip Airway and Jaw Elevation Device During Electrophysiology Procedures: A Single‐Center Experience of 647 Consecutive Cases

Read full text Summarise with VIRAT
Authors: Kotaro Tsuruta, Kensuke Yokoi, Makoto Edayoshi, Kodai Shinzato, Kana Nakashima, Takanori Yamaguchi
Cited by: 0
References: 7

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Background: Safe and stable deep sedation is essential for electrophysiology procedures. We developed a propofol-free deep sedation protocol using the Tulip airway and a jaw elevation device (JED). Methods: This single-center retrospective study analyzed 647 consecutive patients without an anticipated difficult airway (634 atrial fibrillation ablation; 13 left atrial appendage closure) who underwent deep sedation. Endpoints included procedural completion, conversion to intubation, sedation discontinuation, and procedure-related complications. Results: All procedures were completed. One (0.2%) patient required intubation, and 3 (0.5%) experienced procedure-related complications. Conclusion: Deep sedation with the Tulip airway and JED was safe and feasible in selected lower-risk patients.

Fields of Study & Subjects

Anesthesia and Sedative Agents Airway Management and Intubation Techniques Atrial Fibrillation Management and Outcomes

Publication details

Journal / source
Journal of Arrhythmia
Volume
42
Issue
2
Pages
e70323–e70323
Publication date
25 March 2026
Language