Simulation‐free spine palliative radiotherapy enabled by AI‐adapted diagnostic CT

Read full text
Authors: Yiding Han, Alexander Nicola Hanania, Zaid Ali Siddiqui, Vincent Ugarte, Boran Zhou, Abdallah S. R. Mohamed, Piyush Pathak, Daniel Allan Hamstra, Baozhou Sun
Cited by: 0
References: 22

Abstract

BACKGROUND: Radiotherapy planning traditionally requires a dedicated simulation CT (sCT), which can introduce delays in initiating treatment. This is particularly impactful in spinal palliative care, where timely treatment is often important for symptom control and prevention of neurological deterioration. Although diagnostic CT (dCT) is frequently available earlier in the workflow, it can lead to geometric and dosimetric inaccuracies when used directly for treatment planning due to discrepancies in patient positioning, vertebral alignment, and table curvature. PURPOSE: To develop and evaluate an AI-based method that transforms dCT into a simulation-equivalent planning CT (AI-pCT), enabling a clinically feasible simulation-free workflow for spinal palliative radiotherapy. METHODS: Two neural networks were trained to correct spine position and body contour using paired dCT-sCT images from 50 patients (42 train/validation, 8 internal tests) in a safety net hospital and externally evaluated on 7 additional academic medical center (AMC) patients. After rigid bone-based alignment to sCT, dosimetric accuracy was assessed by comparing DVH endpoints (Dmean, Dmax, D95, D99, V100, V107) and DVH Root-Mean-Square (RMS) error for plans recalculated on dCT versus AI-pCT versus sCT. Four radiation oncologists scored image suitability. Significance was evaluated using the Wilcoxon signed-rank test. RESULTS: In the safety net cohort, AI-pCT substantially reduced geometric and dosimetric error relative to dCT (e.g., Dmean error 2.0%→0.57%; RMS DVH error 6.4%→2.2%, all p < 0.05), improved physician plan-quality ratings from "Acceptable" to "Good-Perfect," and increased plan-level clinical goal achievement from 37.5% to 100%. In the AMC cohort, where baseline dCT was already closely aligned to sCT, AI-pCT produced smaller but still statistically significant gains. CONCLUSION: AI-pCT achieves sCT-level geometric and dosimetric fidelity without requiring a separate simulation scan, enabling a simulation-free planning workflow for spinal palliative RT. This approach has the potential to reduce treatment delays and improve access, particularly in resource-constrained environments.

Fields of Study & Subjects

Advanced Radiotherapy Techniques Artificial Intelligence in Healthcare and Education Management of metastatic bone disease

Publication details

Journal / source
Medical Physics
Volume
53
Issue
3
Pages
e70366–e70366
Publication date
26 February 2026
Language
EN