Comparing the In‐Plane Shear Behavior of Glass Fiber‐Reinforced and Carbon Fiber‐Reinforced Polymer Laminates With the Same Epoxy Matrix System in ±45° Tensile Tests

Read full text
Authors: Maria Gfrerrer, Vasco D. C. Pires, Andreas J. Brunner, Clara Schuecker, Gerald Pinter
Cited by: 3
References: 14

Abstract

ABSTRACT The in‐plane shear behavior of glass fiber‐reinforced and carbon fiber‐reinforced epoxy (GF‐ and CF‐epoxy) laminates manufactured with the same matrix system is investigated using quasi‐static ±45° tensile tests. Damage initiation and progression is monitored by optical crack detection for the translucent GF‐epoxy and by acoustic emission (AE) analysis for both materials. The study evaluates different criteria for determining the shear stress, , at failure to obtain ply level rather than laminate level strength values and examines the influence of the transverse stress component, , on measured at failure using classical laminate theory. In GF‐epoxy, optically observed crack initiation or first‐ply‐failure (FPF) coincides with a sharp increase in AE activity, enabling an AE‐based FPF criterion that more accurately represents ply strength than values from ASTM D3518. Besides the AE‐based detection, the ASTM D3039 transition point method provides the most reliable FPF estimates. GF‐epoxy exhibits lower at failure than CF‐epoxy, consistent with the higher resulting contribution arising from lower orthotropy. For both laminates, the shear modulus of elasticity depends on the selected shear angle, , range due to a gradual decrease in the – slope. In GF‐epoxy, maximum AE signal amplitude rate correlates well with optically measured crack density.

Fields of Study & Subjects

Mechanical Behavior of Composites Epoxy Resin Curing Processes Fiber-reinforced polymer composites

Publication details

Journal / source
Polymer Composites
Publisher
Wiley
Volume
47
Issue
12
Pages
11051–11068
Publication date
23 April 2026
Language
EN