Experimental Evaluation of Sample‐Number Dependence of Spatial Resolution in PPRM ‐ OCDR

View at publisher
Authors: Yuta Higa, K. Motoda, Takaki Kiyozumi, Yosuke Mizuno
Cited by: 1
References: 4

Abstract

Periodic pseudo‐random modulation (PPRM) has recently been introduced to improve the spatial resolution of optical correlation‐domain reflectometry (OCDR). In this study, we experimentally examined how the number of samples in one PPRM period affects OCDR performance. The spatial resolution improved as the sample number increased and reached its minimum at approximately 2000 samples, indicating the presence of an optimal sampling condition. These results provide practical guidelines for selecting modulation parameters in PPRM‐OCDR systems. © 2026 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

Fields of Study & Subjects

Optical Polarization and Ellipsometry Surface Roughness and Optical Measurements Optical Coatings and Gratings

Publication details

Journal / source
IEEJ Transactions on Electrical and Electronic Engineering
Publisher
Wiley
Volume
21
Issue
11
Pages
1740-1742
Publication date
31 May 2026
Language