Evaluating chronic bone and soft tissue infections with [68Ga]Ga-Pentixafor PET/CT: a head-to-head comparison with scintigraphy

Read full text
Authors: Dilara Denizmen Zorba, Duygu Has Şimşek, Yasemin Şanlı, Muhammet Ibrahim Karaçam, Ömer Ergin, Arif Atahan Çağatay, Fikret Buyukkaya, Serkan Kuyumcu
Cited by: 2
References: 34

Abstract

Abstract Purpose Chronic bone and soft tissue infections pose a diagnostic challenge, as conventional imaging techniques often show limited sensitivity and specificity. Given that CXCR4 chemokine receptors are expressed on lymphocytes, key mediators of chronic inflammatory response, we hypothesized that CXCR4-targeted imaging may offer enhanced diagnostic accuracy. Accordingly, this study aimed to evaluate the diagnostic performance of [ 68 Ga]Ga-Pentixafor PET/CT in comparison with conventional 3-phase bone scintigraphy and [ 99m Tc]Tc-HMPAO-labelled leucocyte scintigraphy in patients with suspected chronic bone and soft tissue infections. Methods In this retrospective single-centre study, we included patients who underwent both conventional scintigraphic imaging and [ 68 Ga]Ga-Pentixafor PET/CT. Asymptomatic prostheses, orthopaedic implants, and diabetic foot regions within the same cohort served as controls. Two nuclear medicine specialists, blinded to patient data, evaluated imaging findings in consensus visually and quantitatively. Final diagnoses were confirmed by microbiological culture and/or histopathology for infected sites, and by clinical and radiological follow-up for non-infected control sites. Results A total of 20 patients with 25 suspected infectious foci and 14 control sites were evaluated. Of the 25 sites, 21 were confirmed to be infected; no infections were observed in the control sites. Scintigraphy correctly identified 19 infection sites (sensitivity: 90%, specificity: 83%), while [ 68 Ga]Ga-Pentixafor PET/CT was positive in all 21 infection sites, but demonstrated two false-positives (sensitivity: 100%, specificity: 89%). PET/CT showed higher overall accuracy (95% vs. 87%), although this difference did not reach statistical significance ( p = 0.07). Conclusion [ 68 Ga]Ga-Pentixafor PET/CT was accurate in detecting BSTIs, suggesting potential utility as a single-scan imaging approach. These results align with findings from limited prior studies and underscore the need for validation in larger cohorts.

Fields of Study & Subjects

Orthopedic Infections and Treatments Hematological disorders and diagnostics Medical Imaging Techniques and Applications

Publication details

Journal / source
European Journal of Nuclear Medicine and Molecular Imaging
Publisher
Springer Science and Business Media LLC
Volume
53
Issue
5
Pages
3271–3282
Publication date
27 January 2026
Language
EN