The Dementias Platform UK PET/MR harmonisation and test-retest study: assessment of PET repeatability and reproducibility across the national network

Read full text
Authors: Pawel J Markiewicz, Gerard Thompson, Joanna M Wardlaw, Catriona Wimberley, Craig Ritchie, John-Paul Taylor, David Brooks, Ross Maxwell, Michael Firbank, Nigel Hoggard, Li Su, J M WILD
+23 more Philip Hillel, Victoria Rhodes-Bradford, Laura M. Parkes, John T O'Brien, Stephen F. Carter, Franklin I. Aigbirhio, Tim Fryer, Paul M Matthews, Paresh Malhotra, Gabrielle Grey, Will Hallett, Dilek Ocal, John C. Dickson, Enrico De Vita, David L Thomas, Nick C Fox, Giorgios Krokos, Jane E. Mackewn, Paul Marsden, Alexander Hammers, Karl Herholz, Frederik Barkhof, Julian C. Matthews
Cited by: 1
References: 48

Abstract

PURPOSE: Positron emission tomography combined with magnetic resonance imaging (PET/MR) has not yet achieved the level of adoption of PET/CT. This study aimed to harmonise PET imaging protocols across a national PET/MR network and to quantitatively assess whether PET/MR can achieve reliability comparable to PET/CT. While previous PET test-retest studies have demonstrated good repeatability, they have typically been limited to small cohorts or restricted site configurations. METHODS: We conducted a multi-site harmonisation and rigorous test-retest study across the network of eight PET/MR scanners. Thirty-seven healthy older participants (65-90 years) underwent harmonised one-hour amyloid PET/MR scans using either [[Formula: see text]F]flutemetamol or [[Formula: see text]F]florbetaben on two occasions. Retest scans were performed under conditions of same-site repeatability or multi-site reproducibility. Harmonised acquisition and reconstruction protocols were applied, and amyloid burden was quantified on the Centiloid (CL) scale. RESULTS: CL values across 74 scans showed excellent test-retest agreement (ICC = 0.968), improving to 0.987 after exclusion of one attenuation correction related outlier. Mean test-retest variability was 2.58%. No statistically significant differences were observed across repeatability versus reproducibility conditions, scanner types, or tracers. CL measurements were highly consistent with three independent blinded visual reads. CONCLUSION: This study demonstrates that harmonised PET/MR achieves high reliability comparable to PET/CT. Although the accuracy of attenuation maps requires checks, this study supports the use of PET/MR for quantitative amyloid imaging in research and therapeutic trials, and provides a valuable open resource of image and raw PET/MR data for further methodological development.

Fields of Study & Subjects

Dementia and Cognitive Impairment Research Epilepsy research and treatment Medical Imaging Techniques and Applications

Publication details

Journal / source
European Journal of Nuclear Medicine and Molecular Imaging
Publisher
Springer Science and Business Media LLC
Volume
53
Issue
8
Pages
5110–5129
Publication date
29 April 2026
Language
EN