In vivo bacteria-targeted imaging with vancomycin-based positron emission tomography and optical tracers in an orthopaedic trauma implant infection model

Read full text
Authors: Gerbren B. Spoelstra, Lisanne M. Braams, Frank F. A. IJpma, Sjouke Piersma, Carolien S. Braams, Nicholas M. Bernthal, Kevin P. Francis, Andor W.J.M. Glaudemans, Marleen van Oosten, Ben L. Feringa, Wiktor Szymański, Philip H. Elsinga
+1 more Jan Maarten van Dijl
Cited by: 1
References: 36

Abstract

PURPOSE: Prosthetic joint- and fracture-related infections are major postoperative complications. Early, specific, and preferably non-invasive diagnostic tools, such as bacteria-targeting imaging agents, are essential for optimal treatment, since current approaches, including white blood cell scintigraphy and [¹⁸F]FDG-PET, are accurate, but may lack specificity. Vancomycin, an antibiotic targeting Gram-positive bacteria, has been successfully applied as a molecular scaffold for bacteria-specific tracer development. This study evaluated two novel vancomycin-based PET tracers, [¹⁸F]BODIPY-FL-vancomycin and [¹⁸F]VE1-PQ-vancomycin, along with the fluorescent tracer vancomycin-IRDye800CW, for diagnosing biofilm-associated orthopaedic implant infections. METHODS: We employed a preclinical in vivo model of orthopaedic implant infection, where C57BL/6 mice (n = 72) received stainless-steel Kirschner (K)-wire implants in the distal femur, which were inoculated with bioluminescent Staphylococcus aureus or Escherichia coli bacteria, or with PBS (sterile control). At days 13-14 post-implant infection, animals were injected with one of the vancomycin tracers or [¹⁸F]FDG (benchmark control) and underwent PET/CT or fluorescence imaging. Tracer accumulation at the infection site was quantified, followed by biodistribution analysis and bacterial load assessment. RESULTS: F]FDG did not distinguish K-wire infection from sterile controls. Vancomycin-IRDye800CW accumulated specifically at S. aureus infection sites, but not at E. coli infection sites or sterile controls, indicating accurate bacteria-targeted imaging. CONCLUSION: Vancomycin-based PET and optical tracers differentiated bacterial infection from the sterile K-wire controls in a murine model. Optical imaging distinguished Gram-positive from Gram-negative bacterial infection, whereas PET tracers did not. These preclinical findings support further investigation of vancomycin-based tracers for non-invasive imaging of prosthetic joint and fracture-related infections.

Fields of Study & Subjects

Orthopedic Infections and Treatments Bone fractures and treatments Cancer Research and Treatments

Publication details

Journal / source
European Journal of Nuclear Medicine and Molecular Imaging
Publisher
Springer Science and Business Media LLC
Volume
53
Issue
10
Pages
6098–6110
Publication date
19 June 2026
Language
EN