BRF-net: bidirectional spatial–channel fusion and frequency-aware refinement for medical image segmentation

Read full text Summarise with VIRAT
Authors: Lanxiang Ma, Zongjian Yang, Jinghua Zhu, Jiquan Ma
Cited by: 0
References: 56

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Accurate segmentation of anatomical structures in medical images is fundamental to a wide range of clinical applications, from disease diagnosis to treatment planning. However, this task remains persistently challenging due to substantial variations in anatomical scale, ambiguous tissue boundaries, and heterogeneous image appearances. Existing approaches, whether convolutional neural networks or vision transformers, often struggle to simultaneously capture long-range dependencies, preserve fine structural details, and adapt to diverse morphological contexts. To address these limitations, we introduce BRF-Net, a hybrid CNN-Transformer framework that unifies adaptive multi-scale feature aggregation, bidirectional spatial-channel refinement, and frequency-domain detail preservation within a single architecture. Specifically, we propose an Adaptive Gated Multi-Scale (AGMS) block that dynamically selects receptive fields based on image content; a Bidirectional Refinement and Fusion (BRF) Attention Block that enforces reciprocal conditioning between spatial and semantic features; and a Patch-wise Fourier Feed-Forward Network (PF-FFN) that explicitly preserves high-frequency boundary information through learnable spectral filtering. Here we show that BRF-Net achieves state-of-the-art performance across eight diverse public benchmarks covering abdominal organs, cardiac structures, polyps, skin lesions, breast lesions, and nuclei. It surpasses the strongest competing methods by an average of 0.87 points in Dice and 1.45 points in IoU on six binary datasets, while reducing the Hausdorff distance by 4.43. On the multi-organ Synapse dataset, it improves average Dice and IoU by 3.44 and 4.05 points, respectively. These results demonstrate that explicitly coupling scale adaptivity, spatial-semantic consistency, and boundary awareness yields substantial and robust improvements in segmentation fidelity, offering a more reliable tool for clinical image analysis. The source code is publicly available at GitHub and archived in Zenodo with DOI: \url{https://doi.org/10.5281/zenodo.19129179}.

Fields of Study & Subjects

Medical Image Segmentation Techniques Advanced Neural Network Applications Medical Imaging and Analysis

Publication details

Journal / source
The Visual Computer
Volume
42
Issue
14
Pages
605
Publication date
1 November 2026
Language
EN