Clinical performance of the multiplex solid-phase “Direct Strip PCR” for infectious uveitis: a multicenter diagnostic accuracy study

Read full text Summarise with VIRAT
Authors: Satoko Nakano, Sunao Sugita, Hiroshi Takase, Yasuhiro Tomaru, Daisuke Todokoro, Yumi Hasegawa, Yasuhiro Ikeda, Go Mawatari, Chie Sotozono, Kenji Nagata, Kaoru Araki‐Sasaki, Suguru Nakagawa
+52 more Yoshiaki Kiuchi, Kaori Mitoma, Nobuyo Yawata, Takehiro Hariya, Eiichi Uchio, Tomoko Tsukahara‐Kawamura, Hidenori Inoue, Koji Toriyama, Sentaro Kusuhara, Wataru Matsumiya, Nobuyuki Ohguro, Hisashi Mashimo, Ken Fukuda, Waka Ishida, Mariko Egawa, Kei Nakai, Masakazu Morioka, Atsushi Hayashi, Tomoko Nakamura, Yoshihiko Usui, Hiroshi Gotô, Ryohei Nejima, Kazunori Miyata, Kenichi Namba, Keitaro Hase, Annabelle Ayame Okada, Hiroshi Keino, Nobuhisa Mizuki, Masaki Takeuchi, Dai Miyazaki, Kunihiro Kiyosaki, Reiko Kinouchi, Ryoji Yanai, Sho-Hei Uchi, Shigeko Yashiro, Rie Tanaka, Aika Tsutsui, Takashi Suzuki, Yukiko Umeki, Takaaki Yahiro, Akane Sonezaki, Takashi Matsumoto, Tetsuji Ohyama, Masae Kuranari, Naoto Uemura, Yuichi Hori, Atsunobu Takeda, Toshiaki Kubota, Toshikatsu Kaburaki, Koh‐Hei Sonoda, Manabu Mochizuki, the Direct Strip PCR Project Groups
Cited by: 0
References: 34

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

PURPOSE: To evaluate the clinical performance of "Direct Strip PCR," a multiplex solid-phase real-time polymerase chain reaction (PCR) kit, for diagnosing infectious uveitis. STUDY DESIGN: Multicenter, prospective, diagnostic accuracy study METHODS: We analyzed 475 ocular-fluid samples (336 aqueous humor and 139 vitreous fluid) from 29 sites in Japan. Direct Strip PCR, an IVD-grade multiplex real-time PCR kit targeting HSV-1, HSV-2, VZV, EBV, CMV, HHV-6, HTLV-1, Toxoplasma gondii, and Treponema pallidum requiring no DNA extraction and incorporating internal controls, was compared with quantitative PCR (qPCR) for concordance and DNA copy-number correlation. RESULTS: All 9 of the target pathogens were detected. Direct Strip PCR showed excellent agreement with qPCR, with percent positive agreement (PPA), percent negative agreement (PNA), and percent overall agreement (POA) in aqueous humor of 98.0%, 99.2%, and 98.5%, respectively, and in vitreous fluid of 95.7%, 97.1%, and 96.4%, respectively, indicating high concordance for positive and negative results. All the values exceeded predefined 90% thresholds agreed upon with the Pharmaceuticals and Medical Devices Agency, meeting the required performance criteria. Discordant results were infrequent (10/4275 targets) and involved low-copy samples near the detection limit. The DNA copy numbers correlated strongly between the methods (r = 0.948-0.996). No adverse events were reported. CONCLUSION: Direct Strip PCR demonstrated high concordance with qPCR, reliably detected major pathogens of infectious uveitis, and yielded quantitative results that correlated with the qPCR results, supporting disease monitoring. Its solid-phase, extraction-free, and per-run calibration-free format provides a practical basis for regulatory submissions and global dissemination of multiplex PCR.

Fields of Study & Subjects

Ocular Diseases and Behçet’s Syndrome Ocular Infections and Treatments Herpesvirus Infections and Treatments

Publication details

Journal / source
Japanese Journal of Ophthalmology
Volume
70
Issue
4
Pages
966–982
Publication date
2 April 2026