Convolutional neural network for real‑time localization of ganglionated plexi from bipolar intracardiac electrograms

Read full text Summarise with VIRAT
Authors: Tümer Erdem Güler, Metin Çağdaş, Sukriye Ebru Onder, Serdar Bozyel, Nur Dalgıç, Abdülcebbar Şipal, Aziz İnan Çelik, Ahmet Berk Duman, Henry Darchon Huang, Tolga Aksu
Cited by: 0
References: 25

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Abstract Background Precise localization of ganglionated plexi (GP) is critical for effective cardioneuroablation, yet current mapping relies on labour‑intensive stimulation and subjective electrogram (EGM) interpretation. Recent advancements in deep learning (DL) have shown the potential to automate and improve outcomes an atrial fibrillation by analyzing EGMs. We aimed to apply DL to raw bipolar EGMs in order to automate GP detection. Methods A total of 189 760 bipolar windows (18 left‑atrium and 15 right‑atrium maps, respectively) were collected from 18 patients. GP annotation was performed independently by two experienced electrophysiologists. Five atrial maps from three patients were withheld for external testing; the remaining 15 patients yielded 119 222 clean windows for model development (GP prevalence ≈ 3.5%). A lightweight one‑dimensional convolutional neural network (CNN) was implemented using PyTorch. Training used focal loss (α = 0.75, γ = 2.0) and class‑balanced sampling. Performance was assessed with ROC/PR curves, threshold sweeps and gradient‑weighted class activation mapping (GCAM) saliency mapping. Results On the validation set the model achieved 69.6% accuracy; GP precision, recall and F1‑score were 0.09, 0.85 and 0.17, respectively. External testing on 34 976 unseen windows produced ROC‑AUC = 0.870 and PR‑AUC = 0.349. A probability threshold of 0.70 captured 51% of reference GP sites while highlighting anatomically plausible “hot‑spots” (513/9 063 nodes). GCAM consistently focused on central waveform segments (indices 140–160), aligning with fractionated autonomic signatures and reinforcing model interpretability. Conclusions The proposed explainable one‑dimensional CNN detects GP substrates with high sensitivity despite pronounced class imbalance and generalizes to unseen atria. Its probability maps and saliency outputs provide intuitive visual guidance, supporting real‑time, physiology‑aware decision making in cardioneuroablation.

Fields of Study & Subjects

Cardiac Arrhythmias and Treatments ECG Monitoring and Analysis Cardiac electrophysiology and arrhythmias

Publication details

Journal / source
Journal of Interventional Cardiac Electrophysiology
Volume
69
Issue
5
Pages
957–968
Publication date
28 March 2026
Language
EN