Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Read full text
Authors: Ryan Wood, Geon-bo Kim, Igor Jovanovic, C. Lee, Nathan Hines, Tashi Parsons‐Davis
Cited by: 0
References: 13

Abstract

Abstract Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty ( k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.