Comparison of [18F]DPA-814 with [18F]DPA-714 for TSPO Imaging in an Experimental Model

Read full text Summarise with VIRAT
Authors: Julia van der Bie, J. Bakker, Ernst J. Verschoor, Erik Nutma, Jinte Middeldorp, Wissam Beaino, Michael Kassiou, Jonathan J. Danon, Jan A. M. Langermans, Albert D. Windhorst, Marieke A. Stammes
Cited by: 0
References: 27

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Purpose [ 18 F]DPA-714 is a valuable tracer for studying (neuro)inflammation, with well-characterized tracer kinetics and an established imaging window. However, its clinical utility is restricted by the TSPO polymorphism (rs6971), which influences binding affinity in humans. The newly developed tracer [ 18 F]DPA-814 overcomes this limitation and has shown promising results in a preclinical rat model. To further assess its clinical potential, we compared [ 18 F]DPA-814 to [ 18 F]DPA-714 for inflammation imaging in SARS-CoV-2-infected macaques in a longitudinal setting. Procedures Dynamic positron emission tomography (PET) imaging was conducted in four healthy macaques to identify the optimal imaging window for [ 18 F]DPA-814. Four additional macaques were infected with SARS-CoV-2 and monitored for 12 months using whole-body PET-computed tomography (CT) with both tracers. Baseline scans were compared to PET-CTs obtained at 4, 9 and 16 days and at 6 and 12 months post-infection, covering the head, thorax and abdomen. Tracer uptake was assessed in several organs. Results At baseline, [ 18 F]DPA-814 showed higher lung uptake with minimal washout compared to [ 18 F]DPA-714. Although lung lesions developed after infection, [ 18 F]DPA-814 did not demonstrate lesion-specific uptake, unlike [ 18 F]DPA-714. In the brain, the tracers also displayed divergent uptake patterns despite comparable TSPO levels across animals and regions. Conclusions [ 18 F]DPA-814 exhibits a distinct whole-body distribution, particularly in the lungs and brain, in both naïve and SARS-CoV-2-infected macaques compared with [ 18 F]DPA-714, likely reflecting differences in tracer kinetics. Based on these data, [ 18 F]DPA-814 may not fully replace [ 18 F]DPA-714 for lung and brain imaging, and further studies are required to evaluate its suitability in other anatomical regions.

Fields of Study & Subjects

Medical Imaging Techniques and Applications Radiopharmaceutical Chemistry and Applications Neuroinflammation and Neurodegeneration Mechanisms

Publication details

Journal / source
Molecular Imaging and Biology
Volume
28
Issue
3
Pages
502–512
Publication date
1 April 2026
Language
EN