Failure Analysis of a Heat Exchanger in the Sour Water Unit of an Oil Refinery due to Ammonium Bisulfide Corrosion

Read full text
Authors: Jancler Adriano Pereira Nicácio, Vanessa de Freitas Cunha Lins, Leandro de Arruda Santos
Cited by: 1
References: 43

Abstract

Abstract This paper presents a comprehensive failure analysis performed on a shell nozzle of an ammonia rectifier tower heat exchanger belonging to the sour water treatment unit of an oil refinery, which failed in operation. The study investigates the main causes of the failure using ultrasonic thickness measurement techniques, visual inspection, chemical composition, microstructure analysis, scanning electron microscopy, energy-dispersive x-ray spectroscopy, and optical profilometry analysis. Potentiodynamic polarization electrochemical corrosion tests were also performed to select materials that are more resistant to the operating environment. The results indicated that HS − ions react with the iron in carbon steel, promoting metal oxidation and forming corrosion products such as insoluble iron sulfides that deposit on the surface, causing corrosion in the equipment nozzle. This ammonium disulfide corrosion process was the main cause of equipment failure, and as a countermeasure, the nozzle was replaced at this time.

Fields of Study & Subjects

Hydrogen embrittlement and corrosion behaviors in metals Mechanical Failure Analysis and Simulation Corrosion Behavior and Inhibition

Publication details

Journal / source
Journal of Failure Analysis and Prevention
Publisher
Springer Science and Business Media LLC
Volume
26
Issue
2
Pages
559–570
Publication date
23 February 2026