Towards the measurement of porous materials: a comparison between computed X-ray tomography and serial sectioning

Read full text
Authors: Lenarde-Oliver Friedrich, Johannes Stegmann, Oumaima Guissem, Lennart Hinz, Jannes Mevert, Christian Klose, Hans Jürgen Maier, Jörg Seewig
Cited by: 2
References: 30

Abstract

Abstract Characterizing porous metals requires reliable 3D reconstruction. We compare X-ray computed tomography (XCT) and serial sectioning using a virtual ground truth from segmented XCT data. A GPU-based virtual XCT pipeline simulates imaging artifacts, serial sectioning is modeled via extracted topographies and simulated annealing reconstruction. XCT achieves over 98% accuracy but remains sensitive to segmentation thresholding. Serial sectioning captures visible surfaces precisely but cannot measure occluded regions, yielding lower reconstruction accuracy of 91%. Given these complementary strengths, we propose a hybrid approach where CLSM-derived porosity measurements inform XCT threshold selection, grounding this critical parameter in measured sample properties rather than image statistics alone.

Fields of Study & Subjects

Advanced X-ray and CT Imaging Advanced X-ray Imaging Techniques Enhanced Oil Recovery Techniques

Publication details

Journal / source
Production Engineering
Publisher
Springer Science and Business Media LLC
Volume
20
Issue
1
Publication date
19 January 2026
Language
EN