Engineering of bacterial cellulose-based vascular grafts for small-diameter applications

Read full text
Authors: Fusco Deborah, Noor Christiaens, Elia Pederzani, Sara Martinazzi, Giuseppe Isu, Florian Meissner, Jules Miazza, Urs Zenklusen, Michael Gregor, L Koechlin, Alessia Pisanu, Marcello Raimondi Lucchetti
+7 more Gianfranco Beniamino Fiore, Monica Soncini, Katharina Glatz, Alessio Runtgascher, Bernhard Michael Winkler, Friedrich Stefan Eckstein, Anna Marsano
Cited by: 1
References: 39

Abstract

Cardiovascular diseases remain the leading cause of mortality worldwide, necessitating advanced revascularization strategies such as coronary artery bypass grafting (CABG). While autologous vessels like the saphenous vein are commonly used, their limited availability, their potential maladaptation to the arterial environment, and the suboptimal performance of synthetic alternatives underscore the urgent demand for innovative small-diameter grafts. Bacterial Cellulose (BC), synthesized by Acetobacter xylinum , has gained attention due to its excellent biocompatibility, mechanical integrity, and in vivo patency. However, clinical translation is hindered by inconsistent fabrication processes that result in graft mismatched dimensions and variable mechanical performance. This study presents an optimized and reproducible culture method for producing BC-based grafts with clinically relevant dimensions (4 mm inner diameter and 15 cm length). The grafts were evaluated morphologically, biologically and mechanically according to ISO-10993 and ISO-7198 standards, using human saphenous veins as a benchmark. While the veins exhibited high variability in structure (inner diameter: 2.6 ± 0.7 mm; outer diameter: 4.9 ± 1.3 mm) and performance ( e.g. , burst pressure: 577.4 ± 631.3 mmHg), the BC grafts demonstrated consistent morphology (inner diameter: 4.00 mm; outer diameter: 4.92 ± 0.10 mm) and favorable and more reproducible mechanical properties ( e.g. burst pressure: 306.6 ± 96.04 mmHg). In vitro assays confirmed effective bacterial residue removal, low thrombogenicity and preserved the biocompatibility of the cellulose network. Subcutaneous implantation of BC grafts induced a mild inflammatory response, and showed no signs of calcification, in contrast to Gore-tex implants. These findings emphasize the potential of BC grafts as reliable, scalable, and clinically relevant alternatives for vascular substitutes, including pediatric applications, and underscore the importance of standardized production for translational success. • Structural Integrity & Mechanics: BC grafts showed consistent morphology and burst pressure strength values within both physiological and pathological ranges, directly compared to saphenous veins as a benchmark. • Biocompatibility & In Vivo Response: Effective bacterial residue removal ensured biocompatibility, with mild inflammatory responses and no signs of calcification observed in vivo , supporting further pre-clinical studies. • Scalability & Clinical Potential: Reliable production processes showed reproducibility, addressing bioengineering challenges, with promising applications in pediatric procedures.

Fields of Study & Subjects

Advanced Cellulose Research Studies Electrospun Nanofibers in Biomedical Applications Infectious Aortic and Vascular Conditions

Publication details

Journal / source
Biomaterials Advances
Publisher
Elsevier BV
Volume
185
Pages
214851–214851
Publication date
31 March 2026
Language
EN