Evaluation of Ion Chromatography Methods for Bromate Determination in Wastewaters
Abstract
As oxidative processes are increasingly employed for the removal of trace substances in advanced wastewater treatment, as required by, among others, by the EU urban Wastewater treatment directive, disinfection by-products, particularly bromate are becoming increasingly important. This study presents a comprehensive intra- and interlaboratory evaluation of four ion chromatography (IC) based methods for the determination of bromate in wastewater: conductivity detection (IC-CD), post-column reaction with UV/Vis detection (IC-PCR-UV/Vis), high-resolution mass spectrometry (IC-ESI-HRMS), and inductively coupled plasma mass spectrometry (IC-ICP-MS). Performance parameters were assessed in ultrapure water and verified across different wastewater matrices, including influent, secondary clarifier effluent, and final effluent of a municipal wastewater treatment plant. IC-CD achieved a LOQ of 1.4 µg/L in ultrapure water but exhibited strong matrix dependency in untreated wastewater. In treated wastewater, the verified LOQs were sufficiently low to allow quantification below the regulated drinking water limit (10 µg/L). IC-PCR-UV/Vis and IC-ICP-MS demonstrated robust performance across all investigated matrices, with a LOQ of 1.0 µg/L and consistently reliable precision (
Fields of Study & Subjects
Water Treatment and Disinfection
Chemical Analysis and Environmental Impact
Advanced oxidation water treatment
Publication details
- Journal / source
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Volume
- 1785
- Pages
- 467329–467329
- Publication date
- 5 August 2026
- Language
- EN