Ultrasonically anchored core–shell Au–Pt nanoparticles on g-C3N4-modified screen-printed carbon electrode for efficient electrochemical detection of diclofenac in aquatic environments

Read full text
Authors: Sirinyakorn Chinnawat, Ekarat Detsri, Piyathida Thaipukdee, Chakkaphan Pho-ngernngam, Phetradar Jindaphet, Natee Lerdpiriyaskulkij, Akrarath Khattiya, Kongaphisith Tongpoolsomjit, Arjnarong Mathaweesansurn
Cited by: 1
References: 38

Abstract

The widespread occurrence of pharmaceutical residues, particularly diclofenac (DCF), in aquatic environments poses serious ecological and health risks due to their persistence and inefficient removal by conventional treatment systems. This study reports a highly sensitive electrochemical sensor based on a core–shell Au Pt nanoparticles (Au 0 -Pt 0 NPs ) decorated graphitic carbon nitride (g-C 3 N 4 ) heterostructure modified screen-printed carbon electrode (SPCE) for DCF monitoring. The Au 0 -Pt 0 NPs /g-C 3 N 4 nanocomposite was prepared using the ultrasonication method, in which ultrasonic energy facilitated hydrogen bonding between the Au 0 -Pt 0 NPs and g-C 3 N 4 support. The incorporation of Au 0 -Pt 0 NPs onto the g-C 3 N 4 surface provides strong interfacial adhesion, which effectively enhances charge carrier separation and promotes rapid electron transfer across the interface on the SPCE surface during DCF analysis. Optimization of experimental parameter showed that the electrode fabricated at 1.5 mg mL −1 nanocomposite concentration, 15 s interval time analysis, a scan rate of 100 mV s −1 and PBS buffer at pH 7.0 exhibited the highest peak current. The Au 0 -Pt 0 NPs /g-C 3 N 4 /SPCE sensor displayed a wide linear range of 0.25–1000 μmol L −1 , which LOD of 0.25 μmol L −1 , along with excellent reproducibility (%RSD = 1.12%) and stability (%RSD = 0.24%, after storage for 30 day). The electrode demonstrated strong selectivity against interfering species. Validation with aquatic environments samples achieved recoveries of 98.88–103.49%, and ANOVA analysis confirmed no significant difference ( p = 0.527 > 0.05) compared with HPLC results (R 2 > 0.99). The synergistic effect of Au 0 -Pt 0 NPs /g-C 3 N 4 enhanced catalytic performance, making the developed SPCE platform a reliable, and cost-effective sensor for detecting of DCF pollutants.

Fields of Study & Subjects

Electrochemical sensors and biosensors Pharmaceutical and Antibiotic Environmental Impacts Pharmacological Effects and Assays

Publication details

Journal / source
Diamond and Related Materials
Publisher
Elsevier BV
Volume
164
Pages
113494–113494
Publication date
3 March 2026
Language
EN