Energy optimization of reverse osmosis desalination systems in arid regions: A case study in Morocco
Abstract
Reverse osmosis (RO) desalination has become an essential technology for providing freshwater in arid regions; however, its high energy demand remains a major operational and environmental concern. This study investigates the energy optimization of a full-scale RO desalination unit located in southern Morocco. Real operational data were collected and analyzed using a Python-based linear regression model to identify relationships between feed pressure, flow rate, conductivity, and specific energy consumption (SEC). Results show a strong correlation between energy use and operational scheduling, with an optimal operating window reducing SEC from 1.42 to 1.20 kWh m⁻³ and decreasing specific cost by approximately 0.015 USD m⁻³ . Implementation of optimized control strategies led to an estimated 15% reduction in energy consumption and 12% decrease in CO₂ emissions . The proposed three-level methodology data acquisition, operational supervision, and AI-assisted optimization provides a replicable framework for improving the sustainability of desalination plants in energy-constrained arid environments.
Fields of Study & Subjects
Membrane Separation Technologies
Solar-Powered Water Purification Methods
Membrane-based Ion Separation Techniques
Publication details
- Journal / source
- Desalination and Water Treatment
- Publisher
- Elsevier BV
- Volume
- 325
- Pages
- 101637–101637
- Publication date
- 1 January 2026
- Language
- EN