Thermo-economic evaluation of flat plate, evacuated flat plate, and evacuated tube collectors and potential prospect of evacuated flat plate collector in absorption refrigeration system

Read full text Summarise with VIRAT
Authors: Md Ashiqur Rahman, Yasin Khan, M. Monjurul Ehsan, Md. Rezwanul Karim
Cited by: 0
References: 40

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The adoption of solar thermal energy as a clean energy source is increasingly prevalent, particularly in industrial sectors seeking sustainable alternatives to conventional energy sources. While Flat Plate Collector (FPC) is widely adopted and Evacuated Tube Collector (ETC) is used extensively in the commercial sector, the Evacuated Flat Plate Collector (EFPC), a relatively newer technology, is emerging as a viable alternative. Despite growing interest, a comprehensive comparative performance evaluation of FPC, ETC, and EFPC under identical operating and climatic conditions remains largely unexplored. Addressing this gap constitutes the primary objective of the present study. Through a systematic analysis, this study offers insights into the efficiency and effectiveness of these solar collectors, contributing to the broader understanding of solar energy utilization and aiding decision-making processes for sustainable energy solutions. The results demonstrate that ETC and EFPC consistently outperform FPC, particularly at elevated inlet temperatures, highlighting the limitations of FPC for high-temperature use. For instance, at an inlet temperature of 340 K, the FPC outlet temperature increases marginally to 341.33 K, whereas EFPC and ETC achieve substantially higher thermal outputs. At a solar irradiation of 300 W/m², the thermal efficiencies of FPC, EFPC, and ETC are 75.75%, 81%, and 82.7%, respectively, indicating a clear performance advantage of evacuated technologies under low-irradiance conditions. Economic and environmental analyses show that EFPC and ETC provide approximately 2.5%–3% higher fuel cost savings and emission reductions than FPC, with negligible differences between EFPC and ETC. Additionally, the potential integration of EFPC with an absorption refrigeration cycle is examined, demonstrating its applicability for solar-driven cooling. The findings facilitate an enhanced understanding of solar collector performance and aid in facilitating the implementation of sustainable energy solutions in industrial sectors.

Fields of Study & Subjects

Solar Thermal and Photovoltaic Systems Adsorption and Cooling Systems Heat Transfer Mechanisms

Publication details

Journal / source
Energy Reports
Volume
15
Pages
109268–109268
Publication date
24 March 2026
Language
EN