Image quality comparison between low-dose thin-slice deep-learning reconstruction and standard-dose thick-slice hybrid iterative reconstruction in pediatric abdominal CT

Read full text
Authors: Ryota Harai, Yasunori Nagayama, Soichiro Ishiuchi, Ryuya Yoshida, T Inoue, Takumi Osaki, Kaori Shiraishi, Masafumi Kidoh, Seitaro Oda, Takeshi Nakaura, Toshinori Hirai
Cited by: 1
References: 29

Abstract

Objectives To compare image quality between low-dose thin-slice deep-learning reconstruction (DLR) and standard-dose thick-slice hybrid iterative reconstruction (HIR) in pediatric abdominal CT. Methods 82 children (≤6 years) who underwent contrast-enhanced abdominal CT with standard-dose (STD, n = 41) or low-dose (LD, n = 41) protocol matched by age and weight were retrospectively identified. STD and LD images were reconstructed at 3.0-mm using HIR (STD-HIR/3.0 and LD-HIR/3.0, respectively). LD images were also reconstructed at 0.5-mm using HIR (LD-HIR/0.5) and DLR (LD-DLR/0.5). Size-specific dose estimate (SSDE) was compared between groups. Image noise and contrast-to-noise ratio (CNR) were quantified. Noise power spectrum (NPS) and edge-rise slope (ERS) were employed for noise texture and edge sharpness measures, respectively. For subjective evaluation, noise magnitude, noise texture, edge sharpness, delineation of small structures, and diagnostic confidence were rated on a 5-point scale (1 = undiagnostic, 5 = best). Results SSDE was on average 59.5% lower in LD than in STD group (1.7 ± 0.4 vs. 4.2 ± 0.8 mGy, p < 0.001). Image noise was lower in LD-DLR/0.5 compared to STD-HIR/3.0, LD-HIR/3.0, and LD-HIR/0.5 (8.7 ± 1.5, 9.6 ± 1.1, 11.7 ± 1.9, and 17.9 ± 2.3 HU, respectively, all p ≤ 0.017). LD-DLR/0.5 showed equivalent CNR (e.g., liver CNR: 7.1 ± 2.1 vs. 7.0 ± 2.8, p = 0.827) and higher ERS (64.3 ± 23.9 vs. 53.3 ± 10.6 HU/mm, p = 0.011) with similar average NPS frequency (0.281 ± 0.042 vs. 0.291 ± 0.027 mm −1 , p = 0.177) compared to STD-HIR/3.0. Subjective scores for all criteria were higher in LD-DLR/0.5 than in STD-HIR/3.0 (e.g., diagnostic confidence score: 4.5 ± 0.5 vs. 3.4 ± 0.4, p < 0.001). Conclusion Low-dose thin-slice DLR improved edge sharpness, small structure visualization, and diagnostic confidence in pediatric abdominal CT without increasing noise compared to standard-dose thick-slice HIR.

Fields of Study & Subjects

Radiation Dose and Imaging Medical Imaging Techniques and Applications Advanced X-ray and CT Imaging

Publication details

Journal / source
European Journal of Radiology
Publisher
Elsevier BV
Volume
196
Pages
112703–112703
Publication date
29 January 2026
Language
EN