Improved coronary CT angiography image quality using photon-counting detector CT in SCAPIS reexamination: scan protocol and comparative analysis

Read full text
Authors: Mats Lidén, Gusten Nyberg, Marie‐Louise Aurumskjöld, Tomasz Baron, Göran M.L. Bergström, Lilian Henriksson, Tomas Jernberg, Marit Johannesson, David Lind, Henrik Löfmark, Andreï Malinovschi, Anders Persson
+6 more Patrik Nowik, Adrian Pistea, Monica Segelsjö, Franciska Wikner, Mårten Sandstedt, Erika Fagman
Cited by: 1
References: 23

Abstract

OBJECTIVES: The Swedish CArdioPulmonary bioImage Study reexamination (SCAPIS reexamination) is the first population-based study to employ coronary CT angiography (CCTA) using photon-counting detector CT (PCD-CT). It includes 15,000 participants from SCAPIS baseline. This work aims to describe the PCD-CT protocol in SCAPIS reexamination, compare diagnostic image quality with energy-integrating detector CT (EID-CT) at SCAPIS baseline, and assess the comparability of Agatston scores and degree of stenosis between the studies. METHODS: The PCD-CT protocol in SCAPIS reexamination is provided. CCTA data from 1,147 participants in SCAPIS reexamination (51% women, age 65 [IQR 61-69]) and 29,554 participants in SCAPIS (52% women, age 58 [54-61]) were analyzed. The image quality in eleven proximal and middle coronary segments was compared, stratified by Agatston score. Agatston scores and stenosis degree were compared in age- and sex-matched samples. RESULTS: Full diagnostic image quality was more frequent in SCAPIS reexamination (1,036/1,147, 90%) compared with SCAPIS baseline (20,468/26,188, 78%), p < 0.001, despite a higher calcium burden (Agatston score 8 [0-106] vs. 0 [0-20]). Of participants with Agatston score > 400, 89/116, 77%, and 246/945, 26%, had full diagnostic image quality, respectively, p < 0.001. Agatston score distributions and stenosis ≥ 50% were similar in matched samples (p = 0.51 and p = 0.08). Of those with ≥ 50% stenosis at SCAPIS baseline, 30% (12/40) were reclassified to < 50% in SCAPIS reexamination. CONCLUSION: The optimized PCD-CT protocol in SCAPIS reexamination provided high image quality, irrespective of Agatston scores, outperforming the EID-CT protocol used at SCAPIS baseline. Agatston scores were comparable, but potential differences in stenosis grading warrant further investigation.

Fields of Study & Subjects

Advanced X-ray and CT Imaging Cardiac Imaging and Diagnostics Digital Radiography and Breast Imaging

Publication details

Journal / source
European Journal of Radiology
Publisher
Elsevier BV
Volume
201
Pages
112920–112920
Publication date
7 May 2026
Language
EN