Experimental study of thermostat-interface fans towards reducing air-conditioning use

Read full text Summarise with VIRAT
Authors: A. L. Rea, L.H. Corbit, L. H. Shu
Cited by: 0
References: 79

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

To encourage pro-environmental behaviour, we explored whether mechanical fans incorporated into an experimental thermostat interface would affect the temperatures set on prototype thermostats. In warm outdoor conditions, higher thermostat-temperature settings could reduce air-conditioning use in buildings, along with the associated energy expenditure and greenhouse-gas emissions. Of interest to thermostat-interface design is whether one or both of fan visibility and fan airflow sensation are required to encourage more sustainable thermostat adjustments in warm ambient conditions. To experimentally explore the roles of fan visibility and airflow sensation, study participants first set a baseline temperature in an indoor environment. Next, in four similar but separate rooms, participants interacted with four thermostat interfaces. These interfaces varied whether fans were behind a ventilation grill to reduce visibility, and whether fans were behind a solid transparent barrier to block airflow sensation. In the two airflow-sensation conditions, fan speeds were set such that participants would feel similar airflow sensation, regardless of whether the fans were behind a ventilation grill. Participants consisted of 31 university students enrolled in a 4th-year engineering-design course. Results revealed that participants selected significantly higher (more sustainable) temperatures in the airflow-sensation conditions ( Mean (M) = 23.2°C, Standard Deviation (SD) = 3.16) than in the no-airflow-sensation conditions ( M = 20.9°C, SD = 3.73; F-statistic F(1, 30) = 31.148, p-value p < 0.001). In contrast, the visibility of thermostat-interface fans did not significantly affect temperature selections (F(1,30) = 0.168, p = 0.684). These results could be applied to encourage more sustainable use of air-conditioning in residential and office settings where occupants have access to thermostats. In conclusion, enabling airflow sensation while setting the thermostat is a readily implementable behaviour-change intervention to increase pro-environmental occupant behaviour.

Fields of Study & Subjects

Building Energy and Comfort Optimization Innovative Human-Technology Interaction Usability and User Interface Design

Publication details

Journal / source
Energy and Buildings
Volume
361
Pages
117383–117383
Publication date
27 March 2026
Language
EN