Elapsed-time-aware Liquid Neural Networks for direct coarse-interval indoor temperature forecasting in demand-responsive HVAC control
Abstract
Accurate and flexible indoor temperature forecasts are essential for optimizing heating, ventilation, and air conditioning (HVAC) operation, reducing energy consumption, and participating in demand response programs. Fine-resolution forecasts can be post-aggregated when continuous 5-minute measurements and repeated short-interval inference are available, and this strategy is a strong accuracy baseline. This study instead evaluates a fine-to-coarse direct deployment setting in which a Liquid Neural Network (LNN) is calibrated on 5-minute building data and then evaluated directly at 30-minute and 1-hour supervisory-control intervals without retraining or repeated 5-minute inference for the coarse output. The proposed LNN uses elapsed-time-aware continuous-time state updates to rescale the hidden-state transition across these control intervals. Under the single-step direct coarse-interval inference setting, the LNN achieves up to 0.864 in R 2 and 0.017 in coefficient of variation of root mean square error (CV-RMSE), and reduces mean squared error (MSE) by up to 36 % compared with the Transformer-family baselines evaluated under the same direct-inference protocol. In the more demanding 12-step coarse-resolution setting, however, R 2 decreases substantially, indicating that direct long-horizon coarse-interval inference remains challenging; low CV-RMSE values in this setting should be interpreted cautiously because indoor temperature has a high mean and narrow variation range. These results should be interpreted separately from the rolling aggregation regime, where post-aggregated 5-minute forecasts provide the strongest point-accuracy baseline. Additional aggregation-aware comparisons show that direct LNN inference provides a lower-complexity deployment option and remains competitive under same-origin horizon-matched 1-hour evaluation. With only 8950 parameters, over three orders of magnitude fewer than typical attention models, the LNN enables fast, on-device inference suitable for edge HVAC controllers. Additional physical validation shows that the full-model response to an indoor-temperature perturbation has a fitted decay time constant of 14.80 min, close to the estimated air-dominant thermal time constant of 12.56 min. Closed-loop surrogate model predictive control (MPC) simulations further show that the LNN improves the comfort–energy tradeoff under coarser control resolutions, including an 11.54% nominal control-energy proxy reduction relative to Transformer at the 30-minute resolution under better below-setpoint comfort.
Fields of Study & Subjects
Building Energy and Comfort Optimization
Model Reduction and Neural Networks
Smart Grid Energy Management
Publication details
- Journal / source
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Volume
- 365
- Pages
- 121790–121790
- Publication date
- 25 June 2026
- Language
- EN