Investigation of plasterboard fall-off in lightweight floor systems under fire conditions

Read full text Summarise with VIRAT
Authors: Fatheen Hisham, Mahen Mahendran
Cited by: 0
References: 24

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

In lightweight floor systems, fire rated gypsum plasterboards, used as ceiling, play a vital role in providing the required fire resistance level (FRL). The fall-off behaviour of plasterboards in fire and the resulting heat penetration significantly impact the FRL. Plasterboard fall-off temperature and time are key parameters in the fire design of lightweight floor systems. This study has investigated the fire behaviour of gypsum plasterboards in floor-ceiling systems, using the results from 56 full-scale standard fire tests. It revealed that in cavity insulated floor assemblies, while plasterboard fall-off occurred rapidly, the insulation delayed the floor failure after fall-off, unlike in non-insulated floor assemblies where floor failure typically followed shortly after the base layer fall-off. Additionally, minimum failure temperatures were determined for plasterboards used in Australia for each layer in floor assemblies. New suitable equations were then proposed for predicting the plasterboard fall-off times, which can be employed to estimate the FRL by considering ceiling conditions and post-fall-off failure times. This study has provided a good understanding of the fire behaviour of gypsum plasterboards and essential data for estimating the FRL of lightweight floor systems. • The fire behaviour of gypsum plasterboards was investigated using 56 full-scale floor fire tests. • Gypsum plasterboard fall-off was identified as a key factor governing the failure of lightweight floor systems in fire. • Determined the average failure times for both insulated and non-insulated floor configurations post-plasterboard fall-off. • Determined the minimum failure temperatures for plasterboards used in Australia for each layer in floor assemblies. • Proposed suitable equations to predict the plasterboard fall-off times and FRLs of LSF floor systems.

Fields of Study & Subjects

Fire effects on concrete materials Fire dynamics and safety research Heat Transfer and Numerical Methods

Publication details

Journal / source
Fire Safety Journal
Volume
163
Pages
104765–104765
Publication date
25 March 2026
Language
EN