Endocardial ablation of a suspected mid-myocardial or epicardial ventricular tachycardia using a lattice tip ablation catheter: A case report
Abstract
Epicardial ventricular tachycardia (VT) is disproportionately common in non-ischemic cardiomyopathy and is a potential cause for recurrent VT post-ablation. Epicardial ablation has improved outcomes in such cases but is associated with risk including coronary artery and phrenic nerve injury, pericardial effusion/tamponade, and epicardial fat limiting ablation lesion depth, amongst other risks1. Pulsed field ablation (PFA) technologies, either stand alone or in combination with radiofrequency ablation (RFA), may offer strategies for mid-myocardial and epicardial ablation via an endocardial approach.
Fields of Study & Subjects
Cardiac Arrhythmias and Treatments
Cardiac pacing and defibrillation studies
Cardiac electrophysiology and arrhythmias
Publication details
- Journal / source
- HeartRhythm Case Reports
- Volume
- 12
- Issue
- 5
- Pages
- 560–565
- Publication date
- 16 February 2026
- Language
- EN