Pacemaker recovery after permanent pacemaker implantation post-transcatheter aortic valve implantation: A sub-study of the LANDMARK trial

Read full text
Authors: Akihiro Tobe, Pieter C Smits, Niels van Royen, Ignacio J. Amat-Santos, Martin Hudec, Matjaz Bunc, Ben J. L. Van den Branden, Peep Laanmets, Daniel Unić, Bela Merkely, Renicus S. Hermanides, Vlasis Ninios
+30 more Marcin Protasiewicz, Benno J.W.M. Rensing, Pedro L. Martin, Fausto Feres, Manuel De Sousa Almeida, Eric van Belle, Axel Linke, Alfonso Ielasi, Matteo Montorfano, Mark Webster, Konstantinos Toutouzas, Emmanuel Teíger, Francesco Bedogni, Michiel Voskuil, Manuel Pan, Oskar Angerås, Won-Keun Kim, Jürgen Rothe, Ivica Kristić, Vicente Peral, Scot Garg, Geert A. A. Versteeg, Mario García Gomez, Tsung-Ying Tsai, Ashokkumar Thakkar, Udita Chandra, Marie-Claude Morice, Yoshinobu Onuma, Andreas Baumbach, Patrick W. Serruys
Cited by: 1
References: 37

Abstract

BACKGROUND: Conduction system disturbances resulting in permanent pacemaker implantation (PPI) are common complications after transcatheter aortic valve implantation (TAVI). In some patients, there is delayed recovery of the conduction system post-procedure. This study aims to report the incidence and predictors of ventricular pacing (VP) rate≦1% at 1 year after TAVI. METHODS: This is a post-hoc sub-study of the LANDMARK multicentre trial, which randomized 768 patients in a 2:1:1 ratio to the Myval (n = 384) transcatheter heart valve (THV) series or contemporary THVs (Sapien [n = 192] and Evolut [n = 192] series) for the treatment of severe aortic stenosis. Overall, 122 (15.9%) patients underwent PPI within 30 days after TAVI, and 1-year pacemaker follow-up data were retrospectively collected in 99 patients. Pacemaker recovery (PMR) was defined as a VP rate ≦1% at follow-up. RESULTS: PMR occurred in 18% (18/99) of patients. The PMR group was younger than the non-PMR group (78.6 ± 3.0 vs 81.1 ± 5.1 years, p = 0.045). Implantation depth under the non-coronary cusp did not differ between groups (5.7 ± 3.5 vs 5.8 ± 2.8 mm, p = 0.94). There were no significant differences in PMR rates based on THV type: Myval 25% (11/44), Sapien 19% (5/27), and Evolut 7% (2/28) (p = 0.16). In multivariable logistic regression, atrial fibrillation was associated with lower odds of PMR (odds ratio 0.09, 95% confidence interval 0.00-0.77, p = 0.02. CONCLUSIONS: At 1 year, conduction system recovery (VP≦1%) was observed in 18% of patients who underwent PPI after TAVI, with no significant difference among the Myval, Sapien and Evolut series. Atrial fibrillation was associated with lower odds of recovery.

Fields of Study & Subjects

Cardiac Valve Diseases and Treatments Cardiovascular Function and Risk Factors Cardiac pacing and defibrillation studies

Publication details

Journal / source
International Journal of Cardiology
Publisher
Elsevier BV
Volume
456
Pages
134525–134525
Publication date
25 April 2026