Myval Octacor and Octapro Trans-Catheter Heart Valves in Patients with Severe Pure Non Calcified Native Aortic Regurgitation

Read full text
Authors: Alfonso Ielasi, Rodolfo Caminiti, Mariano Pellicano, Andrea Marrone, Dario Pellegrini, Carlo Banfı, Mattia Glauber, Maurizio Tespili
Cited by: 1
References: 20

Abstract

Background: -catheter heart valves (THV). This study sought to evaluate the feasibility, safety, and clinical outcomes following the off-label usage of the Myval Octacor and Octapro balloon-expandable (BE) THV in patients with pure NCAR. Methods: a retrospective cohort analysis was performed on consecutive high-risk surgical patients with severe, pure NCAR who underwent TAVI between January 2023 and June 2025 with the second (Octacor) and third (Octapro) generation of the Myval BE THV. Main end-points were technical and device success according to the Valve Academic Research Consortium (VARC) 3 criteria. The rates of permanent pace-maker implantation (PPI) and moderate-to-severe residual AR both, in-hospital and at the longest available follow-up were also evaluated. Results: during the study period, 32 patients (Octacor, n = 21 and Octapro, n = 11) with pure, NCAR were treated. Mean age was 79.3 ± 7.6 years while 81.2% were male. The mean left ventricular ejection fraction was 43.1 ± 7.4%. An XL size was implanted in 21 patients of whom 15 were 32 mm. The average percentage of THV oversize was 19.7 ± 6.9. Technical success was achieved in 87.5% of the cases due to partial migration of 4 THVs (all 32 mm implanted in large annuli) into the LVOT requiring rescue implantation of a second prosthesis. This strategy was effective in achieving a good result in 2 cases while in the remaining 2, the THVs embolized in the left ventricle requiring surgical conversion. No intraprocedural death or disabling strokes were reported. PPI rate at discharge was 9.4% while moderate residual AR was reported in 1 patient (including patient underwent successful rescue THV-in-THV). Device success was 87.5%. At 1-year follow-up, mortality and PPI rates were 3.1% and 15.6%, respectively with no severe residual AR cases reported. Conclusions: Octacor and Octapro BE THVs implantation in patients with pure NCAR is feasible and yields acceptable clinical outcomes in a high-risk population. Further studies are warranted to better understand the potential role of these THVs in this complex scenario.

Fields of Study & Subjects

Cardiac Valve Diseases and Treatments Congenital Heart Disease Studies Aortic Disease and Treatment Approaches

Publication details

Journal / source
IJC Heart & Vasculature
Publisher
Elsevier BV
Volume
64
Pages
101924–101924
Publication date
16 April 2026
Language
EN