Artificial Intelligence–Enhanced Electrocardiogram Models for Detection of Left Ventricular Dysfunction

Read full text
Authors: Philip M. Croon, Machteld Boonstra, Cornelis P. Allaart, Bauke K.O. Arends, Lovedeep S. Dhingra, Yu-Chang Huang, Thomas G. Mast, Rohan Khera, Chang-Fu Kuo, Joon-Myoung Kwon, Hak Seung Lee, Min Sung Lee
+6 more Rutger R. van de Leur, Zhi-Yong Liu, Evangelos K. Oikonomou, Jasper L. Selder, Michiel M. Winter, Folkert W. Asselbergs
Cited by: 10
References: 49

Abstract

BACKGROUND: Several artificial intelligence-enhanced electrocardiogram (AI-ECG) models have shown promise in detecting left ventricular systolic dysfunction (LVSD), but their head-to-head agreement and performance have not been independently compared within the same cohort. OBJECTIVES: This study aimed to compare the performance of published AI-ECG models for LVSD detection in a standardized external cohort and evaluate the field's transparency and reproducibility. METHODS: We systematically reviewed AI-ECG models predicting LVSD and assessed the risk of bias. Authors were invited to share models for external validation in a well-phenotyped registry of patients undergoing routine clinical cardiac magnetic resonance imaging with cardiologist-adjudicated reports and paired ECGs. Model performance was evaluated in all consecutive patients and a lower-complexity subgroup with 15% LVSD prevalence. RESULTS: We identified 35 studies describing 51 models, reporting high (area under the receiver-operating characteristic curve [AUROC] >0.80) or excellent (AUROC >0.90) performance. The risk of bias is high and primarily attributed to the limited description of development and validation cohort characteristics, as well as the lack of independent external validation. Four groups (from Korea, the United States, Taiwan, and the Netherlands) shared models for independent testing. AUROCs ranged from 0.83 to 0.93 in all patients (n = 1,203; mean age 59 ± 15 years; 450 [35%] female) and from 0.87 to 0.96 in the lower-complexity subset. Performance remained consistent across subgroups, with slight decreases in ECGs showing wide QRS complexes or atrial fibrillation. CONCLUSIONS: In this first-in-kind independent validation and head-to-head comparison study, AI-ECG for LVSD detection demonstrated strong performance despite training on disparate populations. However, the limited-availability of models hinders independent validation.

Fields of Study & Subjects

ECG Monitoring and Analysis Cardiac electrophysiology and arrhythmias Heart Rate Variability and Autonomic Control

Publication details

Journal / source
JACC Advances
Publisher
Elsevier BV
Volume
5
Issue
2
Pages
102572–102572
Publication date
20 January 2026
Language
EN