Novel Use of Dual-Lumen Microcatheter for False Lumen Hematoma Decompression
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
BACKGROUND: Management of iatrogenic coronary dissection is essential for all interventional cardiologists considering its incidence and high associated mortality. CASE SUMMARY: A 66-year-old woman undergoing elective left and right heart catheterization for investigation of shortness of breath experienced iatrogenic catheter-induced ostial right coronary artery dissection. Use of intravascular ultrasound and repurposing a dual-lumen microcatheter enabled successful wiring of true lumen and percutaneous management. DISCUSSION: Novel use and repurposing of available coronary equipment in the form of a dual-lumen microcatheter provided additional tools for management of this dangerous complication. TAKE-HOME MESSAGES: Coronary dissection regardless of mechanism can be fatal and difficult to manage given size differences of the true and false lumen. Use of a dual-lumen microcatheter placed into the false dissection lumen with negative pressure applied can decompress the hematoma and enable wiring of the true lumen for percutaneous management.
Fields of Study & Subjects
Vascular Procedures and Complications
Coronary Interventions and Diagnostics
Coronary Artery Anomalies
Publication details
- Journal / source
- JACC Case Reports
- Volume
- 31
- Issue
- 18
- Pages
- 107511–107511
- Publication date
- 28 March 2026
- Language
- EN