Inadvertent Left Ventricular Implantation of a Leadless Pacemaker Managed by Percutaneous Extraction

Read full text Summarise with VIRAT
Authors: Jonathan K. Schilling, Leili Pourafkari, Ali A. Sovari
Cited by: 0
References: 9

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

BACKGROUND: Although leadless pacemakers minimize lead- and pocket-related complications, their implantation requires a precise technique to avoid rare but serious malposition events. CASE SUMMARY: We present an 84-year-old woman with inadvertent left ventricular (LV) implantation of an Aveir leadless pacemaker. The device was successfully extracted using a carefully executed double-snare technique, followed by new device implantation in the right ventricle. DISCUSSION: There is limited literature guiding the management of inadvertent LV leadless pacemaker implantation, particularly regarding anticoagulation and safe extraction strategies. This case highlights key considerations and demonstrates a successful approach to device removal. TAKE-HOME MESSAGES: As the use of leadless pacemakers increases, so does the potential for related complications, including inadvertent LV implantation. Using multiple fluoroscopic projections during implantation can help ensure correct right ventricular positioning. If LV placement occurs, management-including consideration of anticoagulation and tailored extraction strategies-should be individualized to reduce thromboembolic risk.

Fields of Study & Subjects

Cardiac pacing and defibrillation studies Coronary Interventions and Diagnostics Infective Endocarditis Diagnosis and Management

Publication details

Journal / source
JACC Case Reports
Volume
31
Issue
17
Pages
107548–107548
Publication date
25 March 2026
Language
EN