Balloon-in-Basket Pulsed Field Ablation for Pulmonary Vein Isolation

Read full text
Authors: Atul Verma, Monica Lo, Christopher E. Woods, Ayman A. Hussein, Alok Gambhir, Sri Sundaram, Prashanthan Sanders, David B. DeLurgio, Stavros E. Mountantonakis, Petr Neuzil, Joaquin Osca, Amar Trivedi
+14 more Peter Loh, Hugh Calkins, David Strouse, G B Chierchia, Brett D. Atwater, Jonathan Kalman, Helmut Puererfellner, Antonio Dello Russo, Ramin Davoudi, Richard Schilling, Wenjiao Lin, Amber Miller, Emily Jesser, Dhanunjaya Lakkireddy
Cited by: 2
References: 22

Abstract

BACKGROUND: A novel balloon-in-basket catheter integrated into a mapping system may advance pulsed field ablation (PFA) of atrial fibrillation (AF) with demonstrated deeper lesions, less hemolysis, and promising initial clinical experience. OBJECTIVES: The goal of this study was to assess the 1-year clinical outcomes of the balloon-in-basket PFA system. METHODS: The multicenter VOLT-AF IDE Clinical Study enrolled patients with symptomatic, paroxysmal (PAF), and persistent AF (PeAF) . Pulmonary vein isolation (PVI) was performed with the investigational system. The primary effectiveness endpoint was acute PVI and 12-month freedom from atrial arrhythmia, antiarrhythmic escalation/initiation, cardioversion, or repeat ablation. The primary safety endpoint was device- and/or procedure-related serious adverse events within 7 days of any ablation. Follow-up consisted of 12-lead electrocardiograms at discharge, 3 months, and 12 months; biweekly and symptomatic transtelephonic monitoring; and 24-hour Holter monitoring at 12 months. RESULTS: -VASc score was 2.3 ± 1.6. Left atrial catheter dwell time was 44.1 ± 18.1 minutes (including a 20-minute wait). A mean of 4.6 ± 0.9 applications were delivered per vein. Primary effectiveness was 81.1% (95% CI: 74.3%-86.3%) in PAF and 63.3% (95% CI: 55.1%-70.4%) in PeAF. Freedom from documented arrhythmia recurrence was 84.2% in the PAF group and 67.8% in the PeAF group. Primary safety events occurred in 1.9% of patients, with none in the PAF group. During redo ablation in 19 patients, 78.5% of pulmonary veins remained durably isolated. CONCLUSIONS: This multicenter trial reports high PVI-based effectiveness of the novel balloon-in-basket PFA device with excellent safety.(VOLT-AF IDE Clinical Study; NCT06223789).

Fields of Study & Subjects

Cardiac Arrhythmias and Treatments Atrial Fibrillation Management and Outcomes Microbial Inactivation Methods

Publication details

Journal / source
JACC. Clinical electrophysiology
Publisher
Elsevier BV
Volume
12
Issue
6
Pages
1287–1299
Publication date
5 February 2026
Language
EN