Real-World Outcomes of Dedicated Leaflet Modification for Bioprosthetic Valve-In-Valve TAVR

Read full text
Authors: R K Makkar, Aakriti Gupta, Ignacio Inglessis, Curtiss T. Stinis, P Yadunandan Yadav, Vinod H. Thourani, Stanley J. Chetcuti, Matthew Summers, Vivek Patel, Bassem Chehab, Apurva Patel, Gilbert H.L. Tang
+13 more Sahil Khera, Michael Rinaldi, Trevor Simard, J.H. Southard, Benjamin Ray Stripe, Brian K. Whisenant, Keith Allen, Yoseph Rozenman, Danny Dvir, Carlos E. Sanchez, Jeffrey Popma, Martin B. Leon, Philippe Généreux
Cited by: 1
References: 28

Abstract

BACKGROUND: Coronary obstruction during valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) is infrequent but catastrophic. Mechanical splitting of bioprosthetic leaflets may mitigate this risk, but real-world experience remains limited. OBJECTIVES: The aim of this is to evaluate procedural performance and in-hospital outcomes of a dedicated mechanical leaflet-splitting device in ViV TAVR. METHODS: Consecutive postapproval cases were performed at 28 centers from February to November 2025. Patients were selected for elevated risk based on preprocedural computed tomography criteria, including virtual valve-to-coronary distance ≤4 mm and/or virtual valve-to-sinotubular junction distance ≤3 mm. Procedural outcomes were assessed among patients in whom splitting was attempted; safety outcomes were assessed among all patients in whom the device was introduced. Events were adjudicated using Valve Academic Research Consortium-3 definitions. RESULTS: Among 150 patients (age 78.9 ± 8.5 years; 60.0% female), 95 of 150 (63.3%) underwent ViV TAVR for failed surgical and 55 of 150 (36.7%) for failed transcatheter valves. Computed tomography analysis showed predicted acute coronary obstruction risk in 131 of 150 (87.3%) patients, including combined sinus sequestration and direct ostial obstruction in 76 of 150 (50.7%). Leaflet splitting was attempted in 145 patients and was successful in 144 of 145 (99.3%); dual-leaflet splitting was performed in 83 of 145 (57.2%). Coronary obstruction occurred in 3 of 150 (2.0%; 95% CI: 0.7-5.7). All-cause mortality occurred in 3 of 150 (2.0%; 95% CI: 0.7-5.7), including 2 deaths from left ventricular perforation and 1 after stroke. Conversion to surgery occurred in 2 of 150 (1.3%; 95% CI: 0.4-4.7). CONCLUSIONS: In this early U.S. commercial experience, mechanical leaflet splitting demonstrated high procedural success in an anatomically high-risk ViV TAVR cohort. Serious complications occurred, and longer-term systematic follow-up remains important.

Fields of Study & Subjects

Cardiac Valve Diseases and Treatments Electrospun Nanofibers in Biomedical Applications Orthopaedic implants and arthroplasty

Publication details

Journal / source
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Volume
19
Issue
18
Pages
2459-2470
Publication date
1 June 2026
Language