Secondary hemodialysis catheter malposition associated with azygos vein dilation in the setting of acute hemodynamic changes

Read full text
Authors: Masato Obayashi, Toru Iwahashi, Shun Suzuki, Toshiki Fujiyoshi, Ikki Kojima, Yusuke Shimahara
Cited by: 0
References: 16

Abstract

We report a case of secondary hemodialysis catheter migration into the azygos vein in a 53-year-old critically ill woman. Despite correct initial catheter placement under fluoroscopy, the catheter tip migrated into the azygos arch 4 hours later. Retrospective imaging revealed that the azygos arch had dilated from 3.4 mm to 9.2 mm, likely associated with high positive-pressure ventilation and fluid overload. This case suggests that azygos vein dilation during various procedures may contribute to catheter malposition. These findings indicate that, in critically ill patients, initial imaging alone may be insufficient for accurate catheter placement, suggesting the importance of continuous postprocedural monitoring.

Fields of Study & Subjects

Central Venous Catheters and Hemodialysis Vascular anomalies and interventions Vascular Procedures and Complications

Publication details

Journal / source
Journal of Vascular Surgery Cases and Innovative Techniques
Volume
12
Issue
3
Pages
102227–102227
Publication date
12 March 2026
Language
EN