Highly Repeatable Tissue Proteomics for Kidney Transplant Pathology: Technical and Biological Validation of Protein Analysis Using Liquid Chromatography-Tandem Mass Spectrometry/Mass Spectrometry (LC-MS/MS)

Read full text
Authors: Rianne Hofstraat, Kristina Marx, Renata Blatnik, Nike Claessen, Aleksandra Chojnacka, Hessel Peters Sengers, Sandrine Florquin, Jesper Kers, Garry L. Corthals
Cited by: 0
References: 19

Abstract

Accurate pathological assessment of tissue samples is key to diagnosis and optimal treatment decisions. Traditional pathology techniques suffer from subjectivity, resulting in interobserver variability and limitations in identifying subtle molecular changes. Omics approaches provide both molecular evidence and unbiased classification, which increases the quality and reliability of final tissue assessment. Here, we focus on mass spectrometry (MS)-based proteomics as a method to reveal biopsy tissue differences. For MS data to be useful, molecular information collected from formalin-fixed paraffin-embedded-biopsy tissues needs to be consistent and quantitatively accurate and contain sufficient clinically relevant molecular information. Therefore, we developed an MS-based workflow and assessed the analytical repeatability on 36 kidney biopsies, ultimately analyzing molecular differences and similarities of over 5000 proteins per biopsy. An additional 301 transplant biopsies were analyzed to understand other physical parameters, including the effects of tissue size, standing time in the autosampler, and the effect on clinical validation. MS data were acquired using data-independent acquisition, which provides gigabytes of data per sample in the form of high proteome representation, at exquisitely high quantitative accuracy. The formalin-fixed paraffin-embedded-based method optimized here provides a coefficient of variation 5000 proteins per sample in parallel. We also observed that tissue thickness does affect the outcome of the data quality: 5 μm sections show more variation in the same sample than 10 μm sections. Notably, our data reveal an excellent agreement for the relative abundance of known protein biomarkers with kidney transplantation lesion scores used in clinical pathological diagnostics. The findings presented here demonstrate the ease, speed, and robustness of the MS-based method, where a wealth of molecular data from minute tissue sections can be used to assist and expand pathology, and possibly reduce the interobserver variability.

Fields of Study & Subjects

Advanced Proteomics Techniques and Applications Mass Spectrometry Techniques and Applications Metabolomics and Mass Spectrometry Studies

Publication details

Journal / source
Laboratory Investigation
Volume
106
Issue
3
Pages
106073–106073
Publication date
17 January 2026
Language
EN