Innovative detection of methanol using a copper film–graphene–gold hybrid sensor engineered with 4-nitrothiophenol

Read full text Summarise with VIRAT
Authors: Hassan Hasan Hammud, Chawki Awada, Hawra A. Bukhamsin, Stefano Boscarino, Antonino Scandurra, Francesco Ruffino
Cited by: 0
References: 18

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

We report the development of two novel methanol sensors based on copper film–supported graphene decorated with gold film. Electrode A (Cu/Gr-Au) was fabricated by depositing gold film on a graphene-coated copper film, while electrode B (Cu/Gr-Au-4-NTP) was prepared by further modifying this assembly with 4-nitrothiophenol (4-NTP). Advanced fabrication techniques enabled the preparation of these electrodes with excellent reproducibility and cost-effectiveness. Cyclic voltammetry measurements yielded a detection limit of 10 mM and a detection range of 10–485 mM for both electrode configurations, with sensitivities of 6.4 μA·mM −1 ·cm −2 for electrode A and 18.0 μA·mM −1 ·cm −2 for electrode B. Further electrochemical impedance spectroscopy studies (Z mod) confirmed a detection limit of 10 mM within a 10–485 mM range, with corresponding sensitivities of 0.147 Ω·mM −1 ·cm −2 for electrode A and 0.828 Ω·mM −1 ·cm −2 for electrode B. These findings demonstrate the enhanced performance of the 4-NTP functionalized electrode and underscore the potential of these innovative sensors for sensitive and rapid methanol detection compared to conventional systems. The enhanced performance of electrode B is attributed to the 4-NTP surface modification, which promotes methanol adsorption and facilitates electron transfer, resulting in superior sensitivity compared to electrode A. This work highlights the potential of integrating low-cost materials in sensor design to achieve high linearity, wide dynamic detection ranges, and rapid response times. The promising outcomes of these electrodes pave the way for further investigations into long-term stability, reproducibility, and system integration for real-time methanol monitoring applications. • Deposition of a 7.5 nm-thick Au film on graphene supported on Cu substrate. • Functionalization of the Au film by with 4-nitrothiophenol (4-NTP). • Electrochemical detection of methanol by the Au/Graphene/Cu and 4-NTP/Au/Graphene/Cu electrodes. • By CV measurements, detection limit of 10 mM and linear detection range of 10–485 mM. • Best sensitivity of 18.0 μA·mM −1 ·cm −2 .

Fields of Study & Subjects

Electrochemical sensors and biosensors Electrochemical Analysis and Applications Electrocatalysts for Energy Conversion

Publication details

Journal / source
Microchemical Journal
Volume
224
Pages
117834–117834
Publication date
26 March 2026
Language
EN