Enhancing efficiency and confidence of measurement of metallic material microstructure grain size using ultrasonic array data

Read full text Summarise with VIRAT
Authors: W.G. Wang, Jie Zhang, Paul David Wilcox
Cited by: 0
References: 33

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

In recent work, we adapted the classic backscattering method for conventional transducers to utilize full matrix capture datasets from an ultrasonic array to measure material microstructure grain size, proposing an inverse process that incorporates three-dimensional ultrasonic models. In this paper, we further develop the inverse process to increase its efficiency by using two-dimensional ultrasonic models of the wave field generated by one-dimensional ultrasonic arrays. The computational cost is reduced by a factor of three thousand without compromising calculation accuracy. Experimental validations were performed on a metallic material, copper (EN1652), using ultrasonic arrays with various array element elevation lengths. The measurement uncertainty is also qualified through statistical model. This work will contribute to the eventual use of the developed inverse process for on-line grain size measurements.

Fields of Study & Subjects

Ultrasonics and Acoustic Wave Propagation Non-Destructive Testing Techniques Flow Measurement and Analysis

Publication details

Journal / source
NDT & E International
Volume
161
Pages
103725–103725
Publication date
28 March 2026
Language
EN