Design and validation of a compact extraction and matching system for high current applications

Read full text
Authors: Aristeidis Mamaras, Jean-Baptiste Lallement, Alessandra Lombardi, Francesco Di Lorenzo, Christophe Machado, C. Mastrostefano, Pierre Moyret, Michael O’Neil, Benoit Riffaud, Dimitrios Sampsonidis, František Šanda, Edgar Sargsyan
+2 more Julien Thiboud, Callum Tetrault
Cited by: 1
References: 1

Abstract

ABSTRACT A novel compact extraction system has been developed at CERN to optimize high-current linacs for medical and industrial use. Replacing the traditional LEBT with a 2 cm-long electrode-based design, it enables efficient proton extraction and acceleration to 45 keV. Tested at the Linac4 test stand, both experimental and simulation results confirm its ability to match to the RFQ acceptance with improved beam quality and reduced footprint, offering a viable solution for next-generation compact linacs.

Fields of Study & Subjects

Particle accelerators and beam dynamics Radiation Therapy and Dosimetry Particle Accelerators and Free-Electron Lasers

Publication details

Journal / source
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Publisher
Elsevier BV
Volume
1086
Pages
171324–171324
Publication date
31 January 2026
Language
EN