Ultracold neutron guide-coating facility at U. Winnipeg

Read full text
Authors: T. Hepworth, A. Zahra, B. Algohi, R. de Vries, S. Pankratz, Phyllis Switzer, Thomas Reimer, Mark McCrea, J. W. Martin, Russell Mammei, David Anthony, L. Barrón-Palos
+63 more Michael J. Bossé, Michael P. Bradley, A. Brossard, Tung Thanh Bui, J. Chak, R. Chiba, Charles A. Davis, Kay Drury, Derek Fujimoto, Ryuto Fujitani, Michael Gericke, P. Giampa, C. Gibson, Robert Golub, Takashi Higuchi, Go Ichikawa, Ichiro Ide, Shusaku Imajo, A. Jaison, B. Jamieson, M. Katotoka, S. Kawasaki, Masaaki Kitaguchi, W. Klassen, E. Korkmaz, E. Korobkina, M. Lavvaf, Thomas Werner Lindner, N. Lo, S. Longo, Kirk W. Madison, Y. Makida, John G. Malcolm, J. Mammei, Z. P. Mao, Chris M. Marshall, R. Matsumiya, E. Miller, Meredith M. Miller, K. Mishima, T. Mohammadi, Takamasa Momose, Matthew M. Nalbandian, T. Okamura, Rajiv Patni, R. Picker, Ke Qiao, W. D. Ramsay, W. Rathnakela, DA Salazar, Jun Sato, Wolfgang Schreyer, T. Shima, H. M. Shimizu, S. Sidhu, Shawn Stargardter, R. Stutters, I. Tanihata, Tushar, W. T. H. van Oers, N. Yazdandoost, Q. Ye, M. Zhao
Cited by: 0

Abstract

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm 3 , corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm 3 , corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

Fields of Study & Subjects

Atomic and Subatomic Physics Research Diamond and Carbon-based Materials Research Nuclear Physics and Applications

Publication details

Journal / source
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Volume
1092
Pages
171841–171841
Publication date
11 July 2026
Language
EN