Assessment of post-installed bars in full-scale beam-column joints using different adhesives

Read full text
Authors: Sara Gabriella de Azevedo Cattaneo, Pietro Giuseppe Crespi, Giovacchino Genesio, Manuela Alessandra Scamardo
Cited by: 1
References: 4

Abstract

Beam-column joints represent critical components in reinforced concrete structures. In recent years, the use of post-installed reinforcing bars has become increasingly widespread for such connections, both in the retrofit of existing structures and in new constructions. Several commercial adhesives exhibit bond strengths significantly higher than typical cast-in reinforcing bars capacities, potentially allowing for a reduction in the required anchorage lengths. This study presents experimental results from full-scale tests on two beam-column joints employing post-installed bars, comparing the performance of two adhesives with different mechanical properties. The results are also compared against current design formulations to evaluate their adequacy in predicting the behavior of such connections.

Fields of Study & Subjects

Structural Behavior of Reinforced Concrete Concrete Corrosion and Durability Structural Response to Dynamic Loads

Publication details

Journal / source
Procedia Structural Integrity
Publisher
Elsevier BV
Volume
78
Pages
137–144
Publication date
1 January 2026
Language
EN